Field
Description
Capacity
The amount of raw capacity (in TB) included in the sub-expansion (for
example, 24 TB, 48 TB).
Status
The current status of the storage volume present on the expansion. If the
status is Critical/Error, you will not be able to create volumes or expand the
file system of any unconfigured storage.
Status types for configured storage:
• Green checkmark/OK: This will be shown when all hardware is good, the
RAID volume is present and parity is initialized, and the file system
segments on this volume are online and mounted.
• Amber Exclamation/Warning: Hardware is in a degraded state. This
generic message will be provided when there is a degraded state such as
a redundant disk failure, a predictive disk failure, a redundant PSU
missing or failed, a redundant controller missing or failed, or if there is a
firmware upgrade/downgrade required of disks, enclosure hardware, or a
RAID controller. Check the event log or hardware tree for details.
• Amber Exclamation/Warning: Parity initialization is in progress. This will be
reported when File System expansion has taken place and completed, but
parity initialization is in progress.
• Amber Exclamation/Warning – Filesystem Expansion in progress: This will
be reported when file system expansion is in progress.
• Critical/Error: There is a failure state such as multiple disk failures, inability
to connect to the enclosure (for example, cable or power failure), or the
volume is not online/mounted.
For more detail on unconfigured status types, see the following table.
Storage configuration and reporting
131