Specifications
Environmental specifications
Specification
Value
Temperature range*
Operating
0° C to 40° C (32° F to 104° F)
Nonoperating
-30° C to 65° C (-22° F to 149° F)
Relative humidity (noncondensing)
Operating, maximum wet bulb temperature of 28°C
(82.4°F)
10% to 90%
Nonoperating, maximum wet bulb temperature of
38.7°C (101.7°F)
5% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1.0° per 304.8 m (1.8°F per 1000 ft)
to 3048 m (10,000 ft) is applicable. No direct sunlight allowed.
Mechanical specifications
Specification
Value
Height
4.32 cm (1.70 in)
Depth
38.22 cm (15.05 in)
Width
43.46 cm (17.11 in)
Weight (full load, approximate values)
—
Maximum
8.7 kg (19.14 lb)
Minimum
6.9 kg (15.09 lb)
Power supply specifications
Depending on the installed options and/or the regional location where the server was purchased, the server is
configured with one of the following power supplies:
• HPE DL20 Gen9 290W Non-hot Plug Power Supply
• HPE 900-W AC 240VDC Power Input Module (PN 775595-B21)
This is supported when the two-bay HPE 900-W AC 240VDC RPS Power Backplane option (PN 814835-
B21) is installed.
These are Entry Level Power Supply products for ProLiant servers. For more information about the power
supply features, specifications, and compatibility, see the
Hewlett Packard Enterprise website
.
CAUTION:
Check the system and power supply input ratings before powering up the server.
102
Specifications
Summary of Contents for ProLiant DL20
Page 12: ...12 Customer self repair...
Page 13: ...Customer self repair 13...
Page 14: ...14 Customer self repair...
Page 43: ...b Remove the fan cage c Remove the fan module Fan 1 Removal and replacement procedures 43...
Page 59: ...8 Remove the expansion board Slot 1 Slot 2 Removal and replacement procedures 59...
Page 89: ...Fan locations Fan locations 89...