22.
Install all components removed from the failed system board.
23.
Connect all cables disconnected from the failed system board.
24.
Install the air baffle.
25.
Install the access panel.
26.
Do one of the following:
• Slide the server into the rack.
• Install the server into the rack.
27.
Connect each power cord to the server.
28.
Connect each power cord to the power source.
29.
Power up the server.
30.
If removed, install the security bezel.
After you replace the system board, you must re-enter the server serial number and product ID:
1.
During the server startup sequence, press the
F9
key to access UEFI System Utilities.
2.
Select
System Configuration > BIOS/Platform Configuration (RBSU) > Advanced Options >
Advanced System ROM Options > Serial Number
, then press the
Enter
key.
3.
Enter the serial number and press the
Enter
key. The following message appears:
The serial number should only be modified by qualified service personnel.
4.
To clear the warning, press the
Enter
key.
5.
Enter the serial number and press the
Enter
key.
6.
Select
Product ID
. The following warning appears:
Warning: The Product ID should ONLY be modified by qualified service personnel. This value should
always match the Product ID located on the chassis.
7.
Enter the product ID and press the
Enter
key.
8.
To confirm exiting System Utilities, press the
F10
key.
The server will automatically reboot.
68
Removal and replacement procedures
Summary of Contents for ProLiant DL20
Page 12: ...12 Customer self repair...
Page 13: ...Customer self repair 13...
Page 14: ...14 Customer self repair...
Page 43: ...b Remove the fan cage c Remove the fan module Fan 1 Removal and replacement procedures 43...
Page 59: ...8 Remove the expansion board Slot 1 Slot 2 Removal and replacement procedures 59...
Page 89: ...Fan locations Fan locations 89...
Page 96: ...Four bay SFF hot plug configuration Two bay LFF non hot plug configuration 96 Cabling...