Item
Description
Status
2
If the health LED indicates a degraded or critical state, review the system IML or use iLO to review the
system health status. For more information, see "'Integrated Management Log."'
3
Facility power is not present, power cord is not attached, no power supplies are installed, power supply
failure has occurred, or the power button cable is disconnected.
Table Continued
Power fault LEDs
The following table provides a list of power fault LEDs, and the subsystems that are affected. Not all power
faults are used by all servers.
Subsystem
LED behavior
System board
1 flash
Processor
2 flashes
Memory
3 flashes
Riser board PCIe slots
4 flashes
FlexibleLOM
5 flashes
Removable HPE Flexible Smart Array
controller/Smart SAS HBA controller
6 flashes
System board PCIe slots
7 flashes
Power backplane or storage backplane
8 flashes
Power supply
9 flashes
Rear panel components
Item
Description
1
Slot 1 PCIe/FlexibleLOM
2
Slot 2 PCIe
3
Non-hot-plug power supply
4
Hot-plug power supply 2
5
Hot-plug power supply 1
Table Continued
Power fault LEDs
81
Summary of Contents for ProLiant DL20
Page 12: ...12 Customer self repair...
Page 13: ...Customer self repair 13...
Page 14: ...14 Customer self repair...
Page 43: ...b Remove the fan cage c Remove the fan module Fan 1 Removal and replacement procedures 43...
Page 59: ...8 Remove the expansion board Slot 1 Slot 2 Removal and replacement procedures 59...
Page 89: ...Fan locations Fan locations 89...
Page 96: ...Four bay SFF hot plug configuration Two bay LFF non hot plug configuration 96 Cabling...