15.
Install the heatsink:
a.
Position the heatsink on the processor backplate.
b.
Tighten one pair of diagonally opposite screws halfway, then tighten the other pair of screws.
c.
Finish the installation by completely tightening the screws in the same sequence.
16.
Install the air baffle.
17.
Install the access panel.
18.
Do one of the following:
• Slide the server into the rack.
• Install the server into the rack.
19.
Connect each power cord to the server.
20.
Connect each power cord to the power source.
21.
Power up the server.
22.
If removed, install the security bezel.
54
Removal and replacement procedures