2.
Obtain the latest
fi
rmware
fi
les and save to a temporary location on the host:
a.
Navigate to the MSA1510i support page:
http://www.hp.com/go/support
.
b.
Click the title description of the download option to display important information about the
update.
• Click the
Description
tab for a brief overview about the download.
• Click the
Release Notes
tab for detailed information about the download, including
version information, compatibility information, a summary of changes, important notes,
service considerations, and installation precautions.
IMPORTANT:
Be sure to review the online release notes and readme
fi
les for last-minute noti
fi
cations
about the update.
c.
After reviewing the release notes for update, click
Download
and follow the on-screen instructions
to save the download bundle to a temporary directory on the server.
NOTE:
For downloaded ISO images, create a CD from the downloaded ISO
fi
le using a CD
burning tool with the ability to burn a CD from an ISO
fi
le. Do not simply copy the
ISO
fi
le to a blank CD.
3.
Schedule a maintenance window for the update.
4.
Ensure that there is a valid, recent backup of the system.
5.
Stop all host traf
fi
c to the MSA array.
6.
If the MSA has not been restarted in the last six months, power cycle the array.
7.
Establish a serial connection to the CLI using an emulator program such as HyperTerminal.
NOTE:
the following example describes the HyperTerminal emulator program.
a.
Connect the RJ-45Z end of the custom CLI con
fi
guration cable to the port on the front of the
controller. One custom CLI cable is shipped with the MSA.
b.
Connect the DB9 end of the CLI cable to the serial port on the host server.
c.
Set up a terminal emulator from the host computer using the following settings:
Serial port:
any open COM port
Bits per second:
8
Data bits:
19200
Parity:
none
Stop bits:
1
Flow control:
none
d.
After opening the session, press
Enter
several times to display the CLI command prompt.
1510i Modular Smart Array installation and user guide
85