150 BEACON ON
Informational
The LEDs on the MSA and all
connected hard drives are blinking
because that array controller
was selected for identi
fi
cation
or con
fi
guration in a host-based
application such as the ACU or
SMU.
151 BEACON OFF
Informational
The LEDs on the MSA and all
connected hard drives are no
longer blinking because the
host-based application is no longer
identifying or con
fi
guring this
MSA.
201 ARRAY
CONTROLLER
TEMPERATURE OK
Informational
The temperature sensor on the
array controller indicates that the
temperature that was previously
exceeding the normal operating
range is now back within the
range.
202 ARRAY
CONTROLLER
OVERHEATING
Error
The temperature sensor on the
array controller indicates that
the array controller is starting
to exceed the normal operating
range.
Check all MSA fans and ensure
they are operating. Any failed
fan should be replaced. Ensure
that there is a module or blanking
panel (cover plate) in all MSA
chassis bays and slots. Empty
bays affect the air
fl
ow and cooling
ability of the MSA.
203 ARRAY
CONTROLLER
OVERHEATED
Error
The temperature sensor on the
array controller indicates that the
array controller has exceeded the
safe operating range.
The MSA should be powered
off as soon as possible to avoid
hardware failure.
Check all MSA fans and ensure
they are operating. Any failed
fan should be replaced. Ensure
that there is a module or blanking
panel (cover plate) in all MSA
chassis bays and slots. Empty
bays affect the air
fl
ow and cooling
ability of the MSA.
204 ARRAY
CONTROLLER
DISABLED
Error
The array controller has been
disabled due to a redundancy
failure.
Remove the disabled array
controller, wait 10 seconds, and
then reinsert the array controller,
ensuring that it is fully seated in
the chassis.
If the issue persists, contact HP
support.
205 ARRAY
CONTROLLER
RESTARTING
Informational
The array controller has completed
fi
rmware cloning and is being
restarted automatically.
300 RECOVERY ROM
AUTOFLASH STARTED
Informational
The array controller has detected
that the
fi
rmware's backup
recovery ROM image is invalid
and is copying the current active
fi
rmware image into the backup
recovery ROM.
1510i Modular Smart Array installation and user guide
121
Summary of Contents for StorageWorks 1510i - Modular Smart Array
Page 8: ...8 ...
Page 58: ...58 Installation ...
Page 76: ...76 Configuration ...
Page 104: ...104 Operation and management ...
Page 140: ...140 Regulatory compliance and safety ...
Page 152: ...152 MSA1510i worksheets ...