cache hardware enabled
, 114
cache hardware temporarily disabled
, 115
cache module size
, 114
chassis nvram contents corrupted
, 111
clone
fi
rmware
, 109
cloning refused system halted
, 109
con
fi
gured volumes
, 119
controller too old not supported
, 109
critical lockup detected
, 108
drive failure box, bay
, 117
drive hot added box, bay
, 117
drive hot removed box, bay
, 117
drive position change detected
, 117
drive position change invalid
, 117
dual cache module size mismatch
, 114
ecc corrected memory error seen
, 126
EMU
fl
ash done
, 123
EMU
fl
ash failed
, 123
EMU
fl
ash started
, 123
enable volume
, 108
enable volumes
, 108
fi
rmware
fl
ash done
, 123
fi
rmware
fl
ash failed
, 109
fi
rmware
fl
ash started
, 122
fi
rmware version
, 107
FW version is not supported
, 110
initializing PCI subsystem
, 126
initializing SCSI devices
, 110
initializing SCSI subsystem
, 110
invalid SCSI cabling
, 126
new volume(s) detected
, 120
no cache module found
, 114
no volumes detected
, 120
non-Compaq drive
, 118
obsolete cache data deleted
, 115
online upgrade complete
, 109
online upgrade
fl
ashing done
, 109
online upgrade
fl
ashing failed
, 109
online upgrade
fl
ashing
fi
rmware
, 109
online upgrade
fl
ashing started
, 109
online upgrade incomplete
, 110
online upgrade redundancy halted
, 110
online upgrade restarting system
, 109
PCI bridge ASIC self-test failure
, 126
PCI subsystem hardware failure
, 126
persistent mem disabled
, 126
pilot 2 contrlr not supported
, 109
read failure
, 110
recovery ROM auto
fl
ash done
, 122
recovery ROM auto
fl
ash failed
, 122
recovery ROM auto
fl
ash started
, 121
redundancy active active Controller
, 111
redundancy active standby controller
, 111
redundancy failed cache DIMMS mismatch
,
114
redundancy failed cache size mismatch
, 112
redundancy failed
fi
rmware lockup
, 113
redundancy failed hardware failure
, 111
redundancy failed I/O request error
, 113
redundancy failed mismatch
fi
rmware
, 112
redundancy failed mismatch hardware
, 112
redundancy failed no second controller
, 113
redundancy failed out of memory
, 113
redundancy failed PCI bus error
, 113
redundancy halted expand active
, 112
redundancy halted
fi
rmware cloned
, 112
remove other controller now
, 114
replacement drive found box
, 117
restarting system
, 108
ROM cloning done
, 122
ROM cloning failed
, 122
ROM cloning started
, 122
scanning for SCSI devices
, 110
SCSI subsystem hardware failure
, 110
smart drive alert box
, 117
spares cleared
, 120
startup complete
, 107
storage box
, 124
storage box EMU not responding
, 125
storage box EMU version
, 125
storage box fan failed
, 124
storage box fan hot inserted
, 124
storage box fan hot removed
, 124
storage box
fl
ash done
, 123
storage box
fl
ash failed
, 123
storage box
fl
ash started
, 123
storage box overheated
, 125
storage box overheating
, 125
storage box power supply added
, 125
storage box power supply failed
, 125
storage box power supply ok
, 125
storage box power supply removed
, 125
storage box temperature ok
, 124
storage fan degraded
, 124
system halted for cache error
, 116
system name
, 108
too many volumes detected
, 120
uncorrected ECC memory error seen
, 126
unknown I/O module detected
, 126
valid cache data found at power-up
, 114
volume expansion disabled
, 119
volume expansion failure
, 119
volume initializing parity
, 119
volume media exchanged
, 119
volume rebuild failure
, 119
volume state deleted
, 119
volume state disabled
, 118
volume state expansion active
, 118
volume state failed
, 118
volume state interim recovery
, 118
volume state missing drives
, 119
volume state ok
, 118
volume state rebuilding
, 118
volume state waiting to expand
, 118
volume state waiting to rebuild
, 118
volume state wrong drive replaced
, 119
write failure
, 111
controller display, at startup
, 56
controller, redundancy requirements
, 39
154
Summary of Contents for StorageWorks 1510i - Modular Smart Array
Page 8: ...8 ...
Page 58: ...58 Installation ...
Page 76: ...76 Configuration ...
Page 104: ...104 Operation and management ...
Page 140: ...140 Regulatory compliance and safety ...
Page 152: ...152 MSA1510i worksheets ...