Message
Type
Description
Action
73 CACHE HARDWARE
BATTERIES MISSING
Error
The cache module does not have
its required batteries attached to it.
If the failure occurred on the
standby
array controller, remove
the
standby
array controller,
remove cache, attach cache
batteries, replace the cache
modules, wait 10 seconds, and
then reinsert the array controller,
ensuring that it is fully seated in
the chassis.
If the failure occurred on the
active
array controller, wait until
downtime is available. Power
off the MSA, remove the array
controller, replace the cache
modules, and reinsert the array
controller, ensuring it is fully seated
in the chassis.
Should the issue persist, contact
HP support.
80 REPLACEMENT
DRIVE FOUND BOX
#<n> BAY <n>
Informational
A SCSI hard drive that was
previously missing or failed has
now been replaced with a working
SCSI drive.
81 SMART DRIVE
ALERT BOX #<n>,
BAY <n>
Informational
A SCSI hard drive may be close to
failing. This was determined either
by the hard drive
fi
rmware itself
using SMART technology or by the
array controller using monitor and
performance testing.
The hard drive should be replaced
as soon as possible.
82 DRIVE HOT ADDED
BOX #<n>, BAY <n>
Informational
A SCSI hard drive has been
added to the system in the location
speci
fi
ed in the message.
83 DRIVE HOT
REMOVED BOX #<n>,
BAY <n>
Informational
A SCSI hard drive has been
removed from the system in the
location speci
fi
ed in the message.
84 DRIVE FAILURE
BOX #<n>, BAY <n>
Error
A SCSI hard drive in the system
has failed. If the hard drive was
part of a con
fi
gured volume, then
the state of the volume depends on
the fault tolerance used.
Replace the drive as soon as
possible.
85 BAD DRIVE
FIRMWARE BOX #<n>,
BAY <n>
Error
A SCSI drive has been detected
that has known, bad
fi
rmware
on it. Continued usage of this
drive could result in drive failure,
decreased performance or data
loss.
Update the hard drive
fi
rmware or
replace the hard drive as soon as
possible.
86 DRIVE POSITION
CHANGE DETECTED
Informational
The SCSI hard drives that make
up a con
fi
gured volume have
been physically moved within
the system. The array controller
has updated its con
fi
guration
information accordingly.
87 DRIVE POSITION
CHANGE INVALID
Informational
The SCSI hard drives that make
up a con
fi
gured volume have
been physically moved in such a
way that the array controller can
no longer access the con
fi
gured
volume.
Power the MSA off and restore
drives to their original positions.
1510i Modular Smart Array installation and user guide
117
Summary of Contents for StorageWorks 1510i - Modular Smart Array
Page 8: ...8 ...
Page 58: ...58 Installation ...
Page 76: ...76 Configuration ...
Page 104: ...104 Operation and management ...
Page 140: ...140 Regulatory compliance and safety ...
Page 152: ...152 MSA1510i worksheets ...