c.
Enter the IP address and TCP portal of the target on the primary controller, and then click
OK
. The display returns to the Discovery tab.
(Example: 100.10.1.20:3260)
d.
In multipathing environments only,
repeat step c to add the IP address and TCP portal
of the target on the secondary controller.
NOTE:
As soon as one portal for the MSA is added to the Discovery tab, all portals for the MSA are
automatically discovered by the initiator and will be displayed, whether access to them is
permitted or not. This can be a bit confusing to the user when navigating the iSCSI initiator.
However, if the target has not granted access to the initiator, when a logon is attempted,
access will be denied. With the implementation of iSNS support, iSNS discovery domain
may be put in place to address this issue.
The following illustration shows the Discovery tab after adding the portals to the MSA.
e.
Select the
Targets
tab to con
fi
rm discovery of the target.
64
Con
fi
guration