Table 31 iSCSI or iSCSI/FCoE module log messages
(continued)
iSCSI login of Initiator:
%s
.
Info
App
QLIS_LoginPduContinue:
Initiator: %s
53586
iSCSI login of Target:
%s
.
Info
App
QLIS_LoginPduContinue:
Target: %s
53587
FC login occurred, origin xx (1 = adapter, 2 =
target, 3 = initiator), VP (virtual port) xx, ID (loop
ID) xx.
Info
App
QLFC_Login: Origin 0x%x, VP
Index 0x%x, Id 0x%x
54274
FC login occurred with port ID xx.xx.xx.
Info
App
QLFC_Login: Port ID
%.2x%.2x%.2x
54275
FC login occurred with WWNN
xx.xx.xx.xx.xx.xx.xx.xx.
Info
App
QLFC_Login: Node Name
%.2x%.2x%.2x%.2x%.2x%.2x%.2x%.2x
54276
FC login occurred with WWPN
xx.xx.xx.xx.xx.xx.xx.xx.
Info
App
QLFC_Login: Port Name
%.2x%.2x%.2x%.2x%.2x%.2x%.2x%.2x
54277
QLFC_Logout: Origin 0x%x, VP Index 0x%x, Id
0x%x
Info
App
QLFC_Logout: Origin 0x%x,
VP Index 0x%x, Id 0x%x
54306
FC Logout: Port ID %.2x%.2x%.2x.
Info
App
QLFC_Logout: Port ID
%.2x%.2x%.2x
54307
FC Logout: Node Name xx xx xx xx xx xx xx xx.
Info
App
QLFC_Logout: Node Name
%.2x%.2x%.2x%.2x%.2x%.2x%.2x%.2x
54308
FC Logout: Port Name xx xx xx xx xx xx xx xx.
Info
App
QLFC_Logout: Port Name
%.2x%.2x%.2x%.2x%.2x%.2x%.2x%.2x
54309
FC login event notification, VP (virtual port) xx.
Info
App
QLFC_Logout: Port Name
%.2x%.2x%.2x%.2x%.2x%.2x%.2x%.2x
54359
iSCSI target connection opened for port %d, data
description block (DDB)
%d
.
Info
App
QLIS_OpenConnectionNotification:
Target connection opened
(Port %d, DDB %d)
54683
Event notification; iSCSI open connection request.
Info
App
QLIS_OpenConnectionNotification:
Target connection opened
(Port %d, DDB %d)
54938
Event notification; iSCSI close connection request
or connection closed.
Info
App
QLIS_HandleTeb:
UTM_EC_CLOSE_CONNECTION or
UTM_EC_CONNECTION_CLOSED
54939
Event notification; iSCSI connection closed.
Info
App
QLIS_HandleTeb:
UTM_EC_CLOSE_CONNECTION or
UTM_EC_CONNECTION_CLOSED
54940
Event notification; connection opened with iSNS
server.
Info
App
QLIS_HandleTeb:iSNS Server
Open Connection succeeded
54941
Event notification; iSNS registered state change
notification (RSCN) received.
Info
App
QLIS_HandleTeb:
UTM_EC_ISNS_SCN
54943
Event notification; iSNS client discovered.
Info
App
QLIS_HandleTeb:
UTM_EC_ISNS_CLIENT_DISCOVERED
54945
iSCSI processor SRAM test failed.
Fatal
iSCSI
#%d: qlutm_init: Diagnostic
failed, invalid SRAM
69652
iSCSI processor failed diagnostic reboot.
Fatal
iSCSI
#%d: qlutm_init: Diagnostic
failed, fail reboot
69653
iSCSI processor failed NVRAM diagnostic.
Fatal
iSCSI
#%d: qlutm_init: Diagnostic
failed, invalid NVRAM
69654
270 iSCSI and iSCSI/FCoE module log messages
Summary of Contents for EVA P6000
Page 187: ...German laser notice Italian laser notice Japanese laser notice Laser compliance notices 187 ...
Page 193: ...German battery notice Italian battery notice Battery replacement notices 193 ...
Page 194: ...Japanese battery notice Spanish battery notice 194 Regulatory compliance notices ...