background image

User Manual

ESS-1KW

Energy Storage System

WIFI APP download page

ftp-smartree.y66.dnsnd.com/WIFImonitor.apk

Summary of Contents for ESS-1KW

Page 1: ...User Manual ESS 1KW Energy Storage System WIFI APP download page ftp smartree y66 dnsnd com WIFImonitor apk...

Page 2: ...face 1 4 Product Features 1 5 Warranty Policy 2 6 Basic System Structure 2 7 Installation 3 7 8 WIFI Setting 7 10 9 System Wire Connection 11 13 10 Switching Operation Steps 13 14 11 Solar Panel Selec...

Page 3: ...6 Be very cautious when working with metal tools on or around the energy storage system Dropping a tool may cause a spark or short circuit in batteries or other electrical parts even cause an explosio...

Page 4: ...nsportation or other external force intrusion The transportation methods should be properly selected by the user and the seller just assist to send them to the shipment agent 4 Under the following cir...

Page 5: ...onfirm the following points before installation Do not install the energy storage system on the flammable materials device Install the system on the solid surface to prevent falling off Install the en...

Page 6: ...ts of expansion screws M6 60mm and 3 sets of screws KM5 10mm The screws must be fixed tightly to avoid falling off and hurt others Step 2 Place the energy storage system to hanging bracket Attention W...

Page 7: ...nection ports 1 AC input over current reset breaker 2 AC input port 3 Reserve lithium battery balancing port If the internal lithium battery cells get unbalanced after years use they can be balanced v...

Page 8: ...harging 3 The grid power grid is normal and in the input range 4 Work mode switch is selected to the grid connected mode Timing grid connection mode can be set via APP can set the start time of grid c...

Page 9: ...mode and feeds power to grid the indicator keeps light 2 When it is on grid mode and in standby status it flashes every 3 seconds 3 When it is on grid mode and AC keeps charging it flashes every 0 5...

Page 10: ...Set between 1 40A For example 20 0 means the charge current of 1st charging period is 20A This charging here refers to the mains charging instead of solar charging For solar charger it will be automat...

Page 11: ...harge period The SOC will be compared with the discharge time whichever arrives first and it stops first For example SOC is set as 50 while the discharging feeding to grid time is set as 10 minutes Wh...

Page 12: ...nd discharge period 20 0 Set between 1 20A For example 20 0 means the charge current of 2nd discharging period to grid is 20A This discharging here refers to battery power feeds to grid For example if...

Page 13: ...f solar panel with energy storage system Caution Do not reverse connect the positive and negative poles of solar panel Be careful of electric shock 9 2 1 Place all connection wires at the back side of...

Page 14: ...ed in the package to the AC input port of energy system Make sure all wires are fixed properly and tightly to avoid heating caused by loose or poor contact 9 3 3 Place all connection wires at the back...

Page 15: ...nna to the energy storage system 10 Switching Operation Steps 10 1 Double check if all wires are connected correctly and tightly 10 2 After double confirmation turn on the battery breaker 10 3 Press t...

Page 16: ...he grid power fails or is abnormal it needs work as off grid mode can connect small household loads to the AC output socket running in off grid mode 10 8 Turning off steps are reversed 11 Solar panel...

Page 17: ...ed in somewhere with high temperature and poor ventilation Lithium Battery Protection The LiFePO4 cell is over voltage protection The internal cell is over charged Just disconnect charging and dischar...

Page 18: ...les 25 1500cycles 45 Grid input Parameters 1 Max Power Feed to Grid 600W Max 2 AC Input Current 0 40A Adjustable 3 AC Input Range 90 265VAC 4 AC Input Frequency Range 50HZ 3HZ 5 THDI 3 6 Rectification...

Page 19: ...grid mode grid tied mode and other functions Protection Functions 7 1 IP Level IP21 7 2 Protection Overcharge protection Over discharge protection Over current protection Short circuit protection Ove...

Reviews: