Table 23 Error Messages
(continued)
How to correct
Meaning
Status code value
Snapclone Active
Wait several minutes for the drive
enclosure code load to finish, then
retry the operation.
The operation cannot be completed while
the drive enclosures are undergoing code
load.
111
EMU Load Busy
Change the user name for the new
Continuous Access group or delete the
An existing Continuous Access group
already has this user name.
112
Duplicate User Name
existing Continuous Access group with
the same name.
Allow the drive to finish code load.
The operation is not allowed because the
drive is in a migrate code load state.
113
Drive Reserved For Code Load
Report the error to product support.
This error is no longer supported.
114
Already Presented
Report the error to product support.
This error is no longer supported.
115
Invalid Remote Storage Cell
Retry the operation later. If the error
persists, report the error to product
support.
The SCMI lock context in StorageCell is
empty where the lock is expected to be taken
by the management agent.
116
No Management Interface Lock
Use another Continuous Access group
or remove members from the existing
Continuous Access group.
The specified Continuous Access group
already has the maximum number of
members.
117
Maximum Members
Use an existing destination or stop
using a destination.
The specified Continuous Access group is
attempting to use a new destination past the
maximum number.
118
Maximum Destinations
Populate the user name field.
The user name field for the specified
Continuous Access group is empty.
119
Empty User Name
Use the command form designed to
be used when no storage sell exists
yet.
The command is not valid when a
StorageCell is already formed and the NSC
is operating normally as a member of the
storage cell.
120
Storage Cell Exists
Close the requested session before
attempting this command again.
The requested session is already open on
this NSC. It cannot be opened for multiple
session operation.
121
Already Open
Open the requested session before
attempting this command again.
The requested session was not established
by opening the session.
122
Session Not Open
Case 1: Resolve the RAID inoperative
condition in the disk group.
Case 1: The specified Continuous Access
group cannot complete the operation until
123
Not Marked Inoperative
Case 2: Command is unnecessary on
a non thin provisioned overcommit
virtual disk.
the disk group is marked permanently data
lost.
Case 2: The specified virtual disk is not in
the thin provisioned overcommit state.
Retry the operation later. If the error
persists, report the error to product
support.
Drive activity prevents the operation from
being completed at this time.
124
Media Not Available
Resolve degraded battery situation.
The batteries do not allow the warm plug of
a controller.
125
Battery System Failed
Resolve the cache data lost situation
on the virtual disk.
The virtual disk is cache data lost.
126
Member is Cache Data Lost
Retry the operation later. If the error
persists, report the error to product
support.
The resource needed to execute the request
is in use by internal DRM process. The
operation can be retried later.
127
Internal Lock Collision
171