Limitations
•
HP P6000 Continuous Access is not supported with single path configurations.
Figure 66 OpenVMS configuration
5. SAN switch 1
1. Network interconnection
6. SAN switch 2
2. Single HBA server (Host 1)
7. Controller A
3. Dual HBA server (Host 2)
8. Controller B
4. Management server
Xen configuration
Requirements
•
Switch zoning or controller level SSP must be used to ensure each single path HBA has an
exclusive path to its LUNs.
•
All nodes with direct connection to a disk must have the same access paths available to them.
•
Single path HBA server can be in the same fabric as servers with multiple HBAs.
•
In the use of snapshots and snapclones, the source virtual disk and all associated snapshots
and snapclones must be presented to the single path hosts that are zoned with the same
controller. In the case of snapclones, after the cloning process has completed and the clone
becomes an ordinary virtual disk, you may present that virtual disk as you would any other
ordinary virtual disk.
HBA configuration
•
Host 1 is a single path HBA.
•
Host 2 is a dual HBA host with multipathing software.
See
Figure 67 (page 142)
.
Xen configuration
141