3.
Set up the iSCSI disk on the iSCSI Initiator:
a.
Open the iSCSI Initiator Control Panel applet.
b.
Click the
Targets
tab and then the
Refresh
button to see the available targets
(
Figure 31 (page 88)
). The status should be Inactive.
Figure 31 iSCSI Initiator Properties—Targets tab
c.
Select the target IQN, keying off the module 1 or 2 field and the WWN field, noted in
Step 2.d
, and click
Log On
.
A dialog box opens.
d.
Configure the target IQN:
•
Select the
Automatically
box to restore this connection when the system boots.
•
Select the
Multipathing
box to enable MPIO. The target status is Connected when
logged in.
NOTE:
HP recommends using the Advanced button to selectively choose the Local
Adapter, Source IP, and Target Portal. The Target Portal IP Address is the iSCSI port to
which this initiator connection path is defined.
e.
Depending on the operating system, open
Server Manager
or
Computer Management
.
f.
Select
Disk Management
.
g.
Select
Action > Rescan Disks
. Verify that the newly assigned disk is listed. If not, a reboot
may be required.
h.
Prepare the disk for use by formatting and partitioning.
Multipathing
Microsoft MPIO includes support for the establishment of redundant paths to send I/O from the
initiator to the target. For Windows Server 2008, MPIO is a separate feature that has to be installed
separately. Microsoft iSCSI Software Initiator Version 2.x includes MPIO and has to be selected
for installation. Setting up redundant paths properly is important to ensure high availability of the
target disk. Ideally, the system would have the paths use separate NIC cards and separate network
infrastructure (cables, switches, iSCSI or iSCSI/FCoE modules). HP recommends separate target
ports.
88
iSCSI or iSCSI/FCoE configuration rules and guidelines
Summary of Contents for EVA P6000
Page 187: ...German laser notice Italian laser notice Japanese laser notice Laser compliance notices 187 ...
Page 193: ...German battery notice Italian battery notice Battery replacement notices 193 ...
Page 194: ...Japanese battery notice Spanish battery notice 194 Regulatory compliance notices ...