Show CHAP
Displays CHAP configuration for iSCSI nodes.
None
Authority
show chap
Syntax
Example:
MEZ50 <1>(admin) #> show chap
The following is a list of iSCSI nodes that have been configured
with CHAP 'ENABLED':
Type iSCSI Node
-------- ------------
Init iqn.1991-05.com.microsoft:server1
Show FC
Displays FC port information for the specified port. If you do not specify a port, this command
displays all ports.
None
Authority
[
port_num
]
show fc
Syntax
Identifies the FC or FCoE port to display.
[
port_num
]
Keywords
Example 1:
MEZ75 (admin) #> show fc
FC Port Information
---------------------
FC Port FC1
Port Status Enabled
Port Mode FCP
Link Status Up
Current Link Rate 4Gb
Programmed Link Rate Auto
WWNN 20:00:00:c0:dd:00:00:75 (VPGROUP_1)
WWPN 21:00:00:c0:dd:00:00:75 (VPGROUP_1)
Port ID 00-00-ef (VPGROUP_1)
WWNN 20:01:00:c0:dd:00:00:75 (VPGROUP_2)
WWPN 21:01:00:c0:dd:00:00:75 (VPGROUP_2)
Port ID 00-00-e8 (VPGROUP_2)
WWNN 20:02:00:c0:dd:00:00:75 (VPGROUP_3)
WWPN 21:02:00:c0:dd:00:00:75 (VPGROUP_3)
Port ID 00-00-e4 (VPGROUP_3)
WWNN 20:03:00:c0:dd:00:00:75 (VPGROUP_4)
WWPN 21:03:00:c0:dd:00:00:75 (VPGROUP_4)
Port ID 00-00-e2 (VPGROUP_4)
Firmware Revision No. 5.01.03
Frame Size 2048
Execution Throttle 256
Connection Mode Loop
FC Port FC2
Port Status Enabled
Port Mode FCP
Link Status Up
Current Link Rate 4Gb
Programmed Link Rate Auto
WWNN 20:00:00:c0:dd:00:00:76 (VPGROUP_1)
WWPN 21:00:00:c0:dd:00:00:76 (VPGROUP_1)