Limitations
•
HP P6000 Continuous Access is not supported with single path configurations.
•
Single HBA path at the host server is not part of a cluster, unless in a VMware High Availability
Cluster.
•
Booting from the SAN is supported on single path HBA servers.
Figure 71 VMware configuration
5. SAN switch 1
1. Network interconnection
6. SAN switch 2
2. Single HBA server (Host 1)
7. Controller A
3. Dual HBA server (Host 2)
8. Controller B
4. Management server
Mac OS configuration
For information about Mac OS connectivity, see Mac OS X Fibre Channel connectivity to the HP
StorageWorks Enterprise Virtual Array Storage System Configuration Guide (to download, see
“Related documentation” (page 179)
).
Failure scenarios
HP-UX
Failure effect
Fault stimulus
Extremely critical event on UNIX. Can cause loss of system disk.
Server failure (host power-cycled)
Short term: Data transfer stops. Possible I/O errors.
Long term: Job hangs, cannot umount disk, fsck failed, disk corrupted,
need mkfs disk.
Switch failure (SAN switch disabled)
Short term: Data transfer stops. Possible I/O errors.
Long term: Job hangs, cannot umount disk, fsck failed, disk corrupted,
need mkfs disk.
Controller failure
Short term: Data transfer stops. Possible I/O errors.
Long term: Job hangs, cannot umount disk, fsck failed, disk corrupted,
need mkfs disk.
Controller restart
Mac OS configuration
147