:FSKey
[SOURce:]FREQuency:FSKey <
frequency1
>,<
frequency2
>
sets the two
waveform frequencies for frequency-shift keying. A TTL-compatible high
level on the "Aux In" BNC generates frequency1; a TTL-compatible low
level generates frequency2.
Parameters
Parameter
Name
Parameter
Type
Range of
Values
Default
Units
frequency1
frequency2
numeric
see below |
MINimum | MAXimum
Hz
MINimum selects 0 Hz.
MAXimum selects the current reference oscillator frequency multiplied by
0.468749999767.
The above values bound the legal range for
frequency1
and
frequency2
.
Comments
•
Executable when initiated: Query form only
•
Coupled command: Yes
•
Related Commands:
SOURce:FREQuency:MODE
,
SOURce:FUNCtion:SHAPe
and
USER
,
SOURce:ROSCillator
•
*RST Condition:
SOURce:FREQuency:FSKey 10 kHz
,
15 MHz
Example
Setting the frequency-shift frequencies
FREQ:FSK 1E6,1 KHZ
Set 1 MHz and 1 kHz frequencies
:MODE
[SOURce:]FREQuency:MODE <
mode
>
determines which set of
commands control the frequency subsystem. The settings have the
following meanings:
CW or FIXed:
Selects single-frequency mode.
SOURce:FREQuency:CW|FIXed
selects the waveform frequency.
CW
and
FIXed
are equivalent.
FSKey:
Selects frequency shift keying mode.
SOURce:FREQuency:FSKey
activates the mode, and TTL levels on
the HP E1340A’s front panel "Aux In" BNC are used to toggle
between the two waveform frequencies.
SWEep:
Selects frequency sweep mode.
SOURce:FREQuency:CENTer
,
SPAN
,
STARt
and
STOP
commands set the frequency range. The
SOURce:SWEep
subsystem controls the sweep.
[SOURce:]FREQuency:FSKey
156 HP E1340A Command Reference
Chapter 7
Summary of Contents for E1340A
Page 12: ...Notes 12 HP E1340A Arbitrary Function Generator Module User s Manual ...
Page 14: ...14 HP E1340A Arbitrary Function Generator Module User s Manual ...
Page 42: ...Chapter 2 Generating Standard Waveforms with the HP E1340A 42 ...
Page 54: ...Chapter 2 Generating Standard Waveforms with the HP E1340A 54 ...
Page 58: ...Chapter 3 Generating Arbitrary Waveforms with the HP E1340A 58 ...
Page 84: ...Chapter 4 HP E1340A Sweeping and Frequency Shift Keying 84 ...
Page 130: ...Chapter 6 HP E1340A High Speed Operation 130 ...
Page 202: ...202 HP E1340A SCPI Conformance Information Chapter 7 ...
Page 218: ...218 HP E1340A Specifications Appendix A ...
Page 284: ...284 HP E1340A Register Based Programming Appendix C ...
Page 295: ...Index HP E1340A Arbitrary Function Generator User s Manual 295 ...