C and QuickBASIC
Program Versions
The C example program, CHARGE.C, is in directory “CPROG” and the
QuickBASIC example program, CHARGE.BAS, is in directory
“ QBPROG” on the C and QuickBASIC example disk (part number
E1340-10036).
Generating a Sine
Wave with Spikes
This program generates a Sine Wave with Spikes using 4096 segments or
points.
HP IBASIC Program Example (SPIKES)
This program is similar to the “ SIN_D” BASIC program on page 76, with
the following differences:
1
!RE-SAVE“SPIKES”
2
!This program generates a sine wave with a spike.
•
•
150
!Set AFG parameters
160
OUTPUT @Afg;“SOUR:FREQ:FIX 1E3;”;
!frequency
170
OUTPUT @Afg;“:SOUR:FUNC:SHAP USER;”;
!function
180
OUTPUT @Afg;“:SOUR:VOLT:LEV:IMM:AMPL 1.5V”
!scale
amplitude
190
!
200
!Call subprogram which defines waveform segment.
210
CALL Sine_spike
•
•
310
SUB Sine_spike
320 Sine_spike: !Subprogram which defines a sine wave with a spike
330
COM @Afg,Waveform(*)
340
FOR I=1 TO 4096
350
Waveform(I)=.5*SIN(2*PI*(I/4096))
360
NEXT I
370
Width=50
Continued on next page
79 Generating Arbitrary Waveforms with the HP E1340A
Chapter 3
Summary of Contents for E1340A
Page 12: ...Notes 12 HP E1340A Arbitrary Function Generator Module User s Manual ...
Page 14: ...14 HP E1340A Arbitrary Function Generator Module User s Manual ...
Page 42: ...Chapter 2 Generating Standard Waveforms with the HP E1340A 42 ...
Page 54: ...Chapter 2 Generating Standard Waveforms with the HP E1340A 54 ...
Page 58: ...Chapter 3 Generating Arbitrary Waveforms with the HP E1340A 58 ...
Page 84: ...Chapter 4 HP E1340A Sweeping and Frequency Shift Keying 84 ...
Page 130: ...Chapter 6 HP E1340A High Speed Operation 130 ...
Page 202: ...202 HP E1340A SCPI Conformance Information Chapter 7 ...
Page 218: ...218 HP E1340A Specifications Appendix A ...
Page 284: ...284 HP E1340A Register Based Programming Appendix C ...
Page 295: ...Index HP E1340A Arbitrary Function Generator User s Manual 295 ...