*TST?
*TST?
causes the E1340A to execute its internal self-test and returns a
value indicating the results of the test. The test includes only a test of the
command module-to-card microprocessor communications.
A zero response indicates that the self-test passed. Any non-zero reponse
indicates that the test failed. See the HP E1340A service manual for
information on interpreting non-zero self-test responses.
The settings for all SCPI commands are unchanged by this command.
Comments
•
Executable when initiated: No
•
Coupled command: No
•
*RST Condition: none
*WAI
*WAI
causes the E1340A to wait for all pending operations to complete
before executing any further commands.
If
STATus:OPC:INITiate OFF
is set, command execution resumes when all
commands received prior to the
*WAI
have been executed. If
ON
is set,
*WAI
waits for waveform generation to complete before resuming command
execution.
Comments
•
Executable when initiated: Yes
•
Coupled command: No
•
Related commands:
*OPC, *OPC?
•
*RST Condition: none
*TST?
196 HP E1340A Command Reference
Chapter 7
Summary of Contents for E1340A
Page 12: ...Notes 12 HP E1340A Arbitrary Function Generator Module User s Manual ...
Page 14: ...14 HP E1340A Arbitrary Function Generator Module User s Manual ...
Page 42: ...Chapter 2 Generating Standard Waveforms with the HP E1340A 42 ...
Page 54: ...Chapter 2 Generating Standard Waveforms with the HP E1340A 54 ...
Page 58: ...Chapter 3 Generating Arbitrary Waveforms with the HP E1340A 58 ...
Page 84: ...Chapter 4 HP E1340A Sweeping and Frequency Shift Keying 84 ...
Page 130: ...Chapter 6 HP E1340A High Speed Operation 130 ...
Page 202: ...202 HP E1340A SCPI Conformance Information Chapter 7 ...
Page 218: ...218 HP E1340A Specifications Appendix A ...
Page 284: ...284 HP E1340A Register Based Programming Appendix C ...
Page 295: ...Index HP E1340A Arbitrary Function Generator User s Manual 295 ...