Monitoring and Managing the Director
96
Director Product Manager User Guide
— Invalid Attachment
— Port Failure
— Segmented E_Port
— Link Incident
— Testing
— Inactive
■
Type—The type of port. F_Port displays if an N_Port is attached. E_Port
displays if another E_Port is attached. G_Port displays if the port can function
as either an F_Port or an E_Port, but nothing is currently attached.
■
Alert—This column displays a yellow triangle if a link incident occurs on the
port or if the port's LED is beaconing. Blinking red and yellow diamonds
display for port failures or for ports requiring service. Double-click the row to
display the reason for the status in the Port Properties dialog box.
Double-click a row to choose it, highlight it, and display the Port Properties
dialog box. For an explanation of the fields on the Port Properties dialog box,
refer to “
Displaying Port Information
” on page 85.
Menu Options
Right-click a row to choose it, highlight it, and display a menu with the following
port-related action options. These are the same menu options that display when
you right-click a port in the Port Card View and a port’s bar graph in the
Performance View. You can also click a port or bar graph in the preceding views
and choose the Port option from the Product menu on the menu bar. Refer to
“
Port Menu
” on page 89 for an explanation of these pop-up menu options.
■
Port Properties
■
Node Properties
■
Port Technology
■
Block Port
■
Enable Beaconing
■
Port Diagnostics
■
Channel Wrap (FICON Management Style only)
■
Swap Ports (FICON Management Style only)
■
Clear Link Incident Alert
Summary of Contents for Compaq Presario,Presario 2140
Page 12: ...Contents 12 Director Product Manager User Guide ...
Page 20: ...About this Guide 20 Director Product Manager User Guide ...
Page 66: ...Product Manager Overview 66 Director Product Manager User Guide ...
Page 158: ...Configuring the Director 158 Director Product Manager User Guide ...
Page 204: ...Optional Features 204 Director Product Manager User Guide ...