Configuration procedures—Other environments
92
Operating system-specific notes
NOTE:
SCO UNIX, VMware, OpenVMS, and Tru64 UNIX do not use the provided MSA Support
Software CD. These operating systems use the MSA-CLI to configure the storage and obtain the HBA
drivers and multipathing tools from a different source, such as through operating system updates or
the HP website.
NetWare environments
•
Single-controller configurations are supported for use with active/passive firmware only.
•
Dual-controller configurations are supported for use with either active/passive (using Secure Path
as the multipathing software) or active/active firmware (using the native NetWare MPIO
multipathing software).
•
For information on upgrading the MSA to active/active, see the migration instructions for
NetWare environments, available on the Technical documentation page of the MSA1500
website:
http://www.hp.com/go/msa1500cs
.
•
If desired, NetWare environments can use the Array Configuration Utility to configure the MSA.
The ACU is provided on the MSA Support Software CD and can be installed and run from a
Windows or Linux server, or, the NetWare server can boot to the CD and run the ACU offline
from the CD.
•
If using the ACU to configure the MSA, install Netscape Navigator version 6.2 or later or
Mozilla, version 1.0.2 or later with Personal Security Manager.
•
After installing the MSA, be sure to set the host mode for each NetWare connection to
netware
.
•
If the MSA is upgraded to 6.86 or later active/active firmware, do the following to activate the
native MPIO provided by Novell.
From the console:
a.
Enter
edit
c:\nwserver\startup.ncf
.
b.
Add the following entry as the first line in the
startup.ncf
file:
set multi-path support = on
c.
Locate the following entry and modify it:
d.
For each HBA, verify that the following options are specified:
load ql2x00.ham
slot=x/luns/allpaths/portnames
, where x represents the slot number.
NOTE:
The Native MPIO solution can co-exist with HP Secure Path for NetWare.
Old entry
Modified entry
LOAD SCSIHD.CDM
LOAD SCSIHD.CDM /AEN
Summary of Contents for AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive
Page 60: ...Installation procedures All deployments 60 ...
Page 66: ...Configuration procedures Windows environments 66 ...
Page 72: ...Configuration procedures Linux environments 72 ...
Page 78: ...Configuration procedures HP UX environments 78 ...
Page 84: ...Configuration procedures OpenVMS environments 84 ...
Page 96: ...Configuration procedures Other environments 96 ...
Page 100: ...Powering off and powering on the MSA 100 ...
Page 106: ...Electrostatic discharge 106 ...
Page 126: ...126 ...