HP StorageWorks 1000 Modular Smart Array installation guide
41
NOTE:
Typically, the second Fibre Channel HBA that is initialized during the POST is the
Fibre Channel HBA on the higher slot number. However, because this can change
depending on your server architecture, always check your specific system architecture first.
• Introduce one server model to the SAN at a time to ensure that the MSA retains its defaults;
that is, the front-right controller is the primary and the front-left controller is the secondary.
Then, introduce the next server model following the recommendations above. If there are
multiple failovers/failbacks on the MSA controllers, swap the Fibre Channel cables around at
the end where the servers are introduced to the SAN.
IMPORTANT:
If the active HBA is not correctly configured in the server as described above,
server failover will not occur. If an active server has already failed and failover did not occur
to the passive server, shut down the passive server and cycle the power to ensure that the
MSA1500 is recognized. See ”
Powering off and powering on the MSA
” on page 97 for
instructions.
Summary of Contents for AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive
Page 60: ...Installation procedures All deployments 60 ...
Page 66: ...Configuration procedures Windows environments 66 ...
Page 72: ...Configuration procedures Linux environments 72 ...
Page 78: ...Configuration procedures HP UX environments 78 ...
Page 84: ...Configuration procedures OpenVMS environments 84 ...
Page 96: ...Configuration procedures Other environments 96 ...
Page 100: ...Powering off and powering on the MSA 100 ...
Page 106: ...Electrostatic discharge 106 ...
Page 126: ...126 ...