![background image](http://html.mh-extra.com/html/hp/ad510a-storageworks-modular-smart-array-1500-cs-2u-fibre-channel-san-attach-controller-shelf-hard-drive/ad510a-storageworks-modular-smart-array-1500-cs-2u-fibre-channel-san-attach-controller-shelf-hard-drive_installation-manual_156782093.webp)
HP StorageWorks 1500 Modular Smart Array installation guide
93
If the MSA is upgraded to 6.86 or later active/active firmware, and, if you want to remove the
Secure Path for NetWare driver, do the following:
a.
Follow the removal instructions provided in the Secure Path user documents.
b.
From the console, enter
edit
c:\NWSERVER\STARTUP.NCF
.
c.
Comment out the following entry:
#load hpqsp.cdm
d.
Enter
edit
sys:\system\autoexec.ncf
e.
Comment out the following entries:
Tru64 UNIX environments
•
Single-controller configurations and active/passive firmware are not supported; the MSA must
be upgraded to dual-controllers running active/active firmware.
•
The AlphaServer must have Tru64 UNIX v5.1.b PK4 (or later) installed.
•
The AlphaServer must be configured in a SAN switch zone with the MSA.
•
After installing the MSA, be sure to set the host mode for each Tru64 UNIX connection to
tru64
.
•
For information on upgrading the MSA to active/active, see the migration instructions for Tru64
UNIX environments, available on the Technical documentation page of the MSA1500 website:
http://www.hp.com/go/msa1500cs
.
SCO UNIX environments
•
Dual-controller active/passive configurations are not supported. Dual-controller configurations
must run active/active firmware.
•
Detailed information about deploying an MSA in a SCO UNIX environment is provided in a
separate document available on the Technical documentation page of the MSA1500 website:
http://www.hp.com/go/msa1500cs
. Included in the SCO-specific document are the
procedures for obtaining and installing the HBA drivers for each SCO UNIX operating system.
•
After installing the MSA, be sure to set the host mode for each SCO UNIX connection to
linux
.
LOAD hpqspagt.nlm
LOAD hpqspahw.nlm
Summary of Contents for AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive
Page 60: ...Installation procedures All deployments 60 ...
Page 66: ...Configuration procedures Windows environments 66 ...
Page 72: ...Configuration procedures Linux environments 72 ...
Page 78: ...Configuration procedures HP UX environments 78 ...
Page 84: ...Configuration procedures OpenVMS environments 84 ...
Page 96: ...Configuration procedures Other environments 96 ...
Page 100: ...Powering off and powering on the MSA 100 ...
Page 106: ...Electrostatic discharge 106 ...
Page 126: ...126 ...