HP StorageWorks 1500 Modular Smart Array installation guide
75
•
Direct connect configuration notes:
• For direct connect configurations you must enable FC-AL hard addressing on the MSA
controller. See the ACU or CLI online help or user documentation for instructions.
•
LUN configuration notes:
• In direct connect environments or in any environment when using the ACU-CLI, a minimum of
one storage LUN on the MSA must be configured and set to the HP-UX host mode before
connecting the MSA to the HP-UX server.
Installing the ACU-CLI on the servers (optional)
To use the ACU-CLI to configure MSA storage, perform the following steps to install it on the servers:
NOTE:
•
You must remove earlier versions of the ACU-CLI before installing later versions.
•
For information about using the ACU-CLI, see ACU-CLI online help, the HP-UX ACU-CLI readme
file or release notes, or the HP
Configuring Arrays reference guide
.
1.
Insert the Support Software CD in the CD-ROM drive of the server.
NOTE:
If you created a new Support Software CD from the Web, insert that CD in the
CD-ROM drive of the server and do not use the shipping version of the CD. For more
information, see the following sections in this guide:
• ”
Determine which version of MSA controller firmware to use
” on page 15
• ”
Obtain desired controller firmware and Support Software CD versions
” on page 56
2.
From the console, mount the CD-ROM drive and navigate to the
/HPUXACUCLI/HP-UX
directory
for your environment.
3.
List the contents of the directory and identify the ACU-CLI depot file for your environment.
4.
Copy the ACU-CLI depot file and its corresponding readme file to a temporary directory on the
server. For example:
# cp /HPACUCLI/HP-UX/IA64/HPACUCLI_IA_v7.47-1.depot .tmp
5.
Install the ACU-CLI application using the
swinstall
command. For example:
# swinstall -s /tmp/HPACUCLI_IA_v7.47-1.depot
6.
Remove the Support Software CD from the CD-ROM drive.
NOTE:
To start the ACU-CLI, do the following from the console: Navigate to the
/opt/compaq/hpacucli/bld directory,
and then enter
# ./hpacucli
.
Summary of Contents for AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive
Page 60: ...Installation procedures All deployments 60 ...
Page 66: ...Configuration procedures Windows environments 66 ...
Page 72: ...Configuration procedures Linux environments 72 ...
Page 78: ...Configuration procedures HP UX environments 78 ...
Page 84: ...Configuration procedures OpenVMS environments 84 ...
Page 96: ...Configuration procedures Other environments 96 ...
Page 100: ...Powering off and powering on the MSA 100 ...
Page 106: ...Electrostatic discharge 106 ...
Page 126: ...126 ...