Installation procedures—All deployments
58
•
Runs offline (from a CD) in other ProLiant server environments, such as NetWare.
NOTE:
The ACU is included on the Support Software CD inside the MSA1000/1500 Setup and
Management kit. Instructions for installing the ACU on your server are included in the configuration
chapters of this guide.
For information about using the ACU, see the ACU section of the Configuring Arrays Reference
Guide. This guide is available on the Documentation CD and the Technical documentation page of
the MSA1500 website:
http://www.hp.com/go/msa1500cs
.
For more information about the ACU, see the ACU website:
http://h18000.www1.hp.com/products/servers/proliantstorage/software-management/acumatrix
/index.html
.
NOTE:
When creating arrays, the ACU provides suggested settings. Consider these defaults
(especially the RAID level and rebuild priority) and make sure that they are acceptable according to
your plans.
About the Array Configuration Utility Command Line Interface
The Array Configuration Utility-Command Line Interface (ACU-CLI) is a command line user interface
that can run locally through your browser or remotely through HP Systems Insight Manager
(HP-SIM).
The ACU is supported for use in Windows, Linux, NetWare, and HP-UX environments and can run
locally from the server or remotely through HP Systems Insight Manager (HP-SIM).
NOTE:
The ACU-CLI is included on the Support Software CD inside the MSA1000/1500 Setup
and Management kit. Instructions for installing the ACU-CLI on your server are included in the
configuration chapters of this guide.
For information about using the ACU-CLI, see the ACU-CLI section of the Configuring Arrays
reference guide. This guide is available on the Documentation CD and the Technical documentation
page of the MSA1500 website:
http://www.hp.com/go/msa1500cs
.
For more information about the ACU, see the ACU website:
http://h18000.www1.hp.com/products/servers/proliantstorage/software-management/acumatrix
/index.html
.
Summary of Contents for AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive
Page 60: ...Installation procedures All deployments 60 ...
Page 66: ...Configuration procedures Windows environments 66 ...
Page 72: ...Configuration procedures Linux environments 72 ...
Page 78: ...Configuration procedures HP UX environments 78 ...
Page 84: ...Configuration procedures OpenVMS environments 84 ...
Page 96: ...Configuration procedures Other environments 96 ...
Page 100: ...Powering off and powering on the MSA 100 ...
Page 106: ...Electrostatic discharge 106 ...
Page 126: ...126 ...