Installation procedures—All deployments
48
Connecting Fibre Channel cables in a multipath configuration
Figure 6
shows the Fibre Channel cable connections of an MSA1500 being accessed by two servers
in a multipath configuration. For consistency, cabling should be done like this for active/passive
and active/active configurations.
NOTE:
Multipath configurations must include:
•
Two MSA controllers
•
Two MSA Fibre Channel I/O modules
•
Two Fibre Channel switches
•
Two servers, each with two HBAs
Figure 6
Sample Fibre Channel cable connections, multipath configuration
Connect the
first
Fibre Channel HBA that is initialized during the POST to the active Fibre Channel
interconnect switch (that is, the Fibre Channel SAN switch that is connected to the MSA1500
active
controller—in other words, the controller on the right as you look at the MSA1500 from the front).
Summary of Contents for AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive
Page 60: ...Installation procedures All deployments 60 ...
Page 66: ...Configuration procedures Windows environments 66 ...
Page 72: ...Configuration procedures Linux environments 72 ...
Page 78: ...Configuration procedures HP UX environments 78 ...
Page 84: ...Configuration procedures OpenVMS environments 84 ...
Page 96: ...Configuration procedures Other environments 96 ...
Page 100: ...Powering off and powering on the MSA 100 ...
Page 106: ...Electrostatic discharge 106 ...
Page 126: ...126 ...