Configuration procedures—Windows environments
64
d.
In multipathing environments, install the following components
(required in all dual-controller
configurations)
:
• MPIO Full Featured DSM
• Multipath Manager
IMPORTANT:
When installing the MPIO components, if prompted, remove the Support
Software CD from the CD-ROM drive and restart the server.
5.
After all desired components are installed, remove the Support Software CD from the CD-ROM
drive.
6.
Restart the server.
7.
Repeat these installation procedures on each Windows server that will access the MSA.
NOTE:
To initially start the ACU and enter basic settings, do the following:
•
From the desktop, click
Start>Programs>HP System Tools>hp Array Configuration Utility>Set up
hp Array Configuration Utility
.
•
Click
Next
to set the execution mode (be sure to select Local Application), and then enter
passwords, the device trust mode, and remote access settings.
For complete information about using the ACU to configure the storage, see ACU online help or the
HP Array Configuation Utility User Guide
.
Updating MSA controller firmware (if necessary)
If you need to update the firmware on your MSA controller to a version downloaded from the MSA
website, do so at this time.
For information on determining whether you need to update MSA controller firmware, see the
following sections in this guide:
•
”
Determine which version of MSA controller firmware to use
” on page 15
•
”
Obtain desired controller firmware and Support Software CD versions
” on page 56
For instructions on updating MSA controller firmware, see the
HP StorageWorks Modular Smart
Array 1000/1500 firmware updating guide
, available on the Technical documentation page of the
MSA1500 website:
http://www.hp.com/go/msa1500cs
.
IMPORTANT:
After updating MSA controller firmware, be sure to check the status of the MSA for
unexpected issues. Verify the status of the connections, defined profile types, redundancy settings,
and storage configuration.
Summary of Contents for AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive
Page 60: ...Installation procedures All deployments 60 ...
Page 66: ...Configuration procedures Windows environments 66 ...
Page 72: ...Configuration procedures Linux environments 72 ...
Page 78: ...Configuration procedures HP UX environments 78 ...
Page 84: ...Configuration procedures OpenVMS environments 84 ...
Page 96: ...Configuration procedures Other environments 96 ...
Page 100: ...Powering off and powering on the MSA 100 ...
Page 106: ...Electrostatic discharge 106 ...
Page 126: ...126 ...