Procedure
To replace a power supply in the 4/32 SAN Switch, see
Figure 30
on page 94:
1.
If the switch will remain powered on, verify that the functioning power supply
(the one not being replaced) has been powered on for at least four seconds and
displays a green LED.
2.
If the power supply you are replacing is not already powered off, press the AC
power switch to power it off.
3.
Unplug the power cord from the power supply you are replacing.
4.
Using a Phillips screwdriver, unscrew the captive screw on the power supply you
are replacing.
5.
Remove the power supply from the chassis by pulling its handle out and away
from the chassis.
6.
Orient the new power supply as shown in
Figure 30
on page 94, with the AC
power receptacle on the left.
7.
Gently push the power supply into the chassis until it is firmly seated.
Sc
a
le: 1/4" = 1"
MRO25015a
1
2
3
1. Power supply
2. Captive screw
3. Handle
Figure 30 Installing the power supply in a 4/32 SAN Switch