Table 18 4/32 SAN Switch Power Supply Status LEDs
LED color
Meaning
Corrective action
No light
The power supply is not receiving
power or is off.
Verify that the power supply is on and seated
and that the power cord is connected to a
functioning power source.
Steady green
Power supply is operating
normally.
No action required.
Steady amber
for more than 5
seconds
Power supply fault for one of the
following reasons:
Power cable is disconnected.
Power supply is off.
Power supply has failed.
Try the following:
Check the power cable connection.
Verify that the power supply is powered on.
Replace the power supply.
Items required
Replacing a 4/32 SAN Switch power supply should take less than two minutes and
requires the following items:
•
New power supply
•
Phillips #1 screwdriver
SAN Switch installation guide