LED name
LED color
Hardware status
Recommended action
No light
System is off, boot is not complete,
or boot failed.
Verify that the system is on and
booting is complete.
Steady green System is on and power supplies
are functioning properly.
No action required.
Steady
Amber (for
more than 5
seconds)
Boot failed and system is faulty.
Perform the following steps:
1.
Connect a serial cable to the
system.
2.
Reboot the system.
3.
Check the failure indicated on
the system console.
4.
Contact HP Technical Support.
System Status
Flashing
amber or
green
Attention is required. A number
of variables can cause this status
including a single power supply
failure, a fan failure, or one or
more environmental ranges has
exceeded.
Check the management interface
and the error log for details on the
cause of the status. Contact HP
Technical Support, if necessary.
No light
Port speed is 10 Mb/s.
No action required.
Ethernet
Speed
Steady green Port speed is 100 Mb/s.
No action required.
No light
There is no Ethernet link.
Verify that the Ethernet cable is
connected correctly.
Steady
amber
There is an Ethernet link.
No action required.
Ethernet Link
Flashing
amber or no
light
There is link activity (traffic).
No action required.
86
Managing SAN Switches
Summary of Contents for AA-RWF3A-TE
Page 1: ...HP StorageWorks SAN Switch installation guide Part number AA RWF3A TE Fifth edition May 2007 ...
Page 7: ...Supported HBAs 145 Glossary 147 Index 157 SAN Switch installation guide 7 ...
Page 10: ...10 ...
Page 64: ...64 Installing and configuring SAN Switches ...
Page 90: ...90 Managing SAN Switches ...
Page 117: ...Japanese notice Korean notices SAN Switch installation guide 117 ...
Page 146: ...146 SAN Switch technical specifications ...
Page 156: ...156 Glossary ...