Ensure that the ambient air temperature does not exceed 40 ºC (104 ºF) while
the switch is operating.
NOTE:
Do not block air vents. The switch uses ambient air for cooling.
Installing the switch as a stand-alone device
To install the switch as a stand-alone unit:
1.
Unpack the switch and verify that all items listed in
Shipping carton
contents
on page 35 are present.
2.
Locate the four rubber feet in the accessory box.
3.
Apply the adhesive rubber feet to the switch. The rubber feet help prevent the switch
from sliding off the supporting surface:
a.
Clean the indentations at each corner of the bottom of the switch to ensure that
they are free of dust or other debris that might lessen the adhesion of the feet.
b.
With the adhesive side against the chassis, place one rubber foot in each
indentation and press into place.
4.
Place the switch on a flat, sturdy surface.
5.
Apply power to the switch as described in
Powering on and off
on page 66.
CAUTION:
Do not connect the switch to the network until the IP address is set. For instructions on
setting the IP address, see
Cabling and configuring the SAN Switch
on page 52.
40
Installing and configuring SAN Switches
Summary of Contents for AA-RWF3A-TE
Page 1: ...HP StorageWorks SAN Switch installation guide Part number AA RWF3A TE Fifth edition May 2007 ...
Page 7: ...Supported HBAs 145 Glossary 147 Index 157 SAN Switch installation guide 7 ...
Page 10: ...10 ...
Page 64: ...64 Installing and configuring SAN Switches ...
Page 90: ...90 Managing SAN Switches ...
Page 117: ...Japanese notice Korean notices SAN Switch installation guide 117 ...
Page 146: ...146 SAN Switch technical specifications ...
Page 156: ...156 Glossary ...