NOTE:
Figure 17
illustrates how to attach the plenum to the 4/8 or 4/16 SAN Switch
specifically. If installing the plenum on the 4/32B SAN Switch, the procedure and
figure also applies.
IO
IO
I
!
25052a
1
2
AT
TE
NT
IO
N:
M
axim
um
scr
ew
le
ng
th
fo
r ra
ck
m
ou
nt
ing
to
be
5m
m
o
r 1
3/6
4 in
.
3
Figure 17 Attaching the Plenum to the 4/8 or 4/16 SAN Switch
1. Plenum
2. SAN Switch
3. Two screws for attaching plenum to rails
Securing the switch to the outer rails
To secure the switch to the outer rails:
1.
Insert the switch with the attached inner rails into the outer rails.
NOTE:
This step applies to installing a switch in HP 9000 Series, HP 10000
Series or HP System/e racks.
2.
Insert the device into the rack and install (2) #10-32 x 1/2-inch Phillips pan-head
screws with captive star lock washers with one on each side. See
Figure 18
and
Figure 19
.
50
Installing and configuring SAN Switches