CRC
Cyclic redundancy check. A check for transmission errors that
is included in every data frame.
defined zone con-
figuration
The set of all zone objects defined in the fabric. May
include multiple zone configurations.
See also
zone
,
zone
configuration
.
directory service
See
SNS
.
DLS
Dynamic load sharing. Dynamic distribution of traffic over
available paths. Allows for recomputing of routes when an
Fx_Port or E_Port changes status.
domain ID
Unique identifier used in routing frames for all switches in a
fabric. Usually assigned by the principal switch, but can be
assigned manually. The domain ID for an HP switch can be any
integer between 1 and 239. The default domain ID is usually 1.
E_D_TOV
Error-detect time-out value. The minimum time a target waits
for a sequence to complete before initiating recovery. Can
also be defined as the maximum time allowed for a round-trip
transmission before an error condition is declared.
E_Port
Expansion port. A type of switch port that can be connected
to an E_Port on another switch to create an ISL.
See also
ISL
trunking
,
U_Port
.
EE_Credit
End-to-end credit. The number of receive buffers allocated by
a recipient port to an originating port. Used by Class 1 and
Class 2 services to manage the exchange of frames across the
fabric between source and destination.
enabled zone con-
figuration
The currently enabled configuration of zones. Only one
configuration can be enabled at a time.
See also
zone
,
zone
configuration
.
end-to-end flow
control
A facility that governs flow of class 1 and class 2 frames
between N_Ports.
error
With respect to FC, a missing or corrupted frame, time-out, loss
of synchronization, or loss of signal (link error).
exchange
The highest-level FC mechanism used for communication
between N_Ports. Composed of one or more related
sequences; can work in one or both directions.
F_Port
Fabric port. A port that is able to transmit under fabric protocol
and interface over links. Can be used to connect an N_Port
to a switch.
See also
U_Port
.
148
Glossary
Summary of Contents for AA-RWF3A-TE
Page 1: ...HP StorageWorks SAN Switch installation guide Part number AA RWF3A TE Fifth edition May 2007 ...
Page 7: ...Supported HBAs 145 Glossary 147 Index 157 SAN Switch installation guide 7 ...
Page 10: ...10 ...
Page 64: ...64 Installing and configuring SAN Switches ...
Page 90: ...90 Managing SAN Switches ...
Page 117: ...Japanese notice Korean notices SAN Switch installation guide 117 ...
Page 146: ...146 SAN Switch technical specifications ...
Page 156: ...156 Glossary ...