10.
Verify that the LED on the new power supply displays a steady green light while the
switch is operating (see
Table 18
on page 93). If the LED is not green, make sure
that the power supply is firmly seated.
Fabric OS identifies the power supplies in a 4/64 SAN Switch from left to right as
PS2 and PS1, as shown in
Figure 34
on page 102.
Replacing the 4/64 SAN Switch fan assembly
The 4/64 SAN Switch contains three fan assemblies, as shown in
Figure 35
. Fabric OS
identifies the fans from left to right as Fan 3, Fan 2, and Fan 1.
S
cale: 1/
8
" = 1"
ATT
EN
TIO
N:
Ma
xim
um
scr
ew
len
gth
for
rack
mo
untin
g to
be
5m
m o
r 13
/64
in.
S
cale:
5/16" = 1"
251
8
5a
1
4
2
3
1. Nonport side of switch
2. Fan assembly 3
3. Fan assembly 2
4. Fan assembly 1
Figure 35 4/64 SAN Switch fan assemblies on the nonport side
SAN Switch installation guide
103
Summary of Contents for AA-RWF3A-TE
Page 1: ...HP StorageWorks SAN Switch installation guide Part number AA RWF3A TE Fifth edition May 2007 ...
Page 7: ...Supported HBAs 145 Glossary 147 Index 157 SAN Switch installation guide 7 ...
Page 10: ...10 ...
Page 64: ...64 Installing and configuring SAN Switches ...
Page 90: ...90 Managing SAN Switches ...
Page 117: ...Japanese notice Korean notices SAN Switch installation guide 117 ...
Page 146: ...146 SAN Switch technical specifications ...
Page 156: ...156 Glossary ...