Creating the Stream of Generated and Expected Data
How to Specify Events and Reactions to Events
152
HP 81200 Data Generator/Analyzer Platform User Guide, Revision 2.1
How to Fill In the Branch Table
Each block has its own branch table.
1
Open the context menu of block 2.
2
Choose
View / Edit Branches
.
If no reactions have been specified so far, an empty branch table
appears.
Figure 75
Empty Branch Table
3
Click the Add button.
Now you can see how the table is built up: If the specified event
occurred, go to a certain block of the sequence and/or output a trigger at
the clock module and/or set the VXI trigger lines.
Figure 76
Branch Table Structure
4
In the
IF
column, select one of the available events. The display starts
with the lowest-priority event that has been defined (see also
).
The pull-down menu offers also the DEFAULT event. This is a deferred
event which occurs at the end of a block and which must not be defined.
It has a lower priority than any user-defined event and can be used to
change the normal flow (which is either continuation or iteration).