brief description
Level
Parameter
Factory setting b
ioL
yt (8)
Factory setting b
ioL
yt (13)
Factory setting b
ioL
yt (15)
Factory setting b
ioL
yt (23)
Factory setting b
ioL
yt (25)
Factory setting b
ioL
yt (31)
Factory setting b
ioL
yt (36)
System settings
a
ccess
Unit
Maximum
Setting range
Start meter calibration
COUNTER
PARAMETER 01
OFF
HF
–
ON
Pellet throughput (kg/ h) at
100% modulating stoker
speed of rotation
COUNTER
PARAMETER 02
11
HF
kg/h
200
Consumption meter 1
COUNTER
USAGE 1
BE
kg
Consumption meter 2
COUNTER
USAGE 2
BE
kg
Meter «Empty ash box»
COUNTER
ASH BOX
BE
kg
Meter «Clean boiler»
COUNTER
CLEANING
HF
kg
Meter «Forced cleaning»
COUNTER
FORCED CL.
HF
kg
Reset pellet meter 1
Consumption meter 1
COUNTER
RESET BURN. 1
OFF
BE
–
SET
Reset pellet meter 2
Consumption meter 2
COUNTER
RESET BURN. 2
OFF
BE
–
SET
Reset pellet meter 3
«Empty ash box»
COUNTER
RESET ASH
OFF
BE
–
SET
Reset pellet meter 4
«Clean boiler»
COUNTER
RESET CLEAN
OFF
BE
–
SET
Timeout discharge
FILLING
PARAMETER 01
45
HF
min
480
Filling off-period 1 Start
FILLING
PARAMETER 06
12:30
BE
Time 24:00
Filling off-period 1 Stop
FILLING
PARAMETER 07
15:30
BE
Time 24:00
Filling off-period 2 Start
FILLING
PARAMETER 08
22:00
BE
Time 24:00
Filling off-period 2 Stop
FILLING
PARAMETER 09
07:00
BE
Time 24:00
Filling system
OFF: manual filling
1: Pneumatic (suction turbine)
2: Continuous filling
3: Suction probe with
switching unit
FILLING
PARAMETER 15
3
HF/
OEM
3
Number of suction probes
1: One suction probe
2: Two suction probes
3: Three suction probes
FILLING
PARAMETER 17
3
HF/
OEM
3
Selection of suction probe
AUTO: automatic suction
probe switchover
1: Only probe 1 active
2: Only probe 2 active
3: Only probe 3 active
FILLING
PARAMETER 18
AUTO
HF/
OEM
3
Filling run time
BURNER
PARAMETER 04
10
HF
s
600
Max. speed of rotation
pressure fan
BURNER
PARAMETER 26
20
20
20
23
23
24
25
HF
%
100
Max. speed of rotation
modulating stoker
BURNER
PARAMETER 27
18
26
30
46
50
58
65
HF
%
100
Max. speed of rotation
induced-draught fan
BURNER
PARAMETER 28
65
65
70
75
50
50
55
HF
%
100
Min. speed of rotation
pressure fan
BURNER
PARAMETER 29
1
2
3
5
6
7
8
HF
%
100
Min. speed of rotation
modulating stoker
BURNER
PARAMETER 30
4
8
10
12
15
17
20
HF
%
100
AUTOMATIC FIRING DEVICE FFA 101
45
4 211 326 / 01
OvERvIEW Of SETTIngS
Summary of Contents for 30-BioLyt 13