2.3.4 Fitting the burner
1. Remove the ash wiper ring (1, Figure 09) from
the burner plate (1a) to facilitate insertion of the
burner (1c).
1
3a
1b
1a
3
Figure 09
2. To do this, turn the ash wiper ring with the marking
(Figure 10) towards the recess. Use a felt-tip marker
to mark the ash wiper ring on the opposite side
(for «front»); this makes later installation easier.
Lift the ring at the arrow marking on the rear and pull
it away from the burner plate.
Figure 10
3. Loosen the two screws (3, Figure 09) of the secondary
air connection (3a) and
pull the secondary air
connection off
; this makes it easier to insert the
burner into the bottom section.
7. Fold the insulation mat back into place and secure
with the tension springs.
The connection between the bottom
section and the heat exchanger must seal
tightly!
If possible, now pressure-test the bottom
section with the heat exchanger, checking
for leakage (mains water pressure is
sufficient).
If a leak is not detected until after the
electrical connections and the casing
have been installed, it is much more
difficult to remedy the fault.