3.2
Technical data
Type
(8)
(13)
(15)
(23)
(25)
(31)
(36)
•
Nominal heat output
kW
7.9
13.0
14.9
23.0
24.9
31.0
36.0
•
Firing capacity with nominal heat output
kW
8.3
13.7
15.6
24.2
26.3
32.3
37.5
•
Heat output range
kW
2.1-7.9
3.9-13.0 4.4-14.9 6.5-23.0 7.3-24.9 8.7-31.0 9.8-36.0
•
Pellets
Ø
mm
6
6
6
6
6
6
6
Length mm
5-30
5-30
5-30
5-30
5-30
5-30
5-30
• Maximum boiler flow temperature
°C
75
75
75
75
75
75
75
•
Minimum boiler operating temperature
°C
60
60
60
60
60
60
60
•
Minimum boiler return temperature
°C
40
40
40
40
40
40
40
•
Flue gas temperature with nominal heat output
°C
120
120
120
120
120
120
120
•
Flue gas temperature at lowest heat output
°C
90
90
90
90
90
90
90
•
Carbon dioxide CO
2
%
11
11
12
12
13
13
13
•
Operating/test pressure
bar
3.0/4.5
3.0/4.5
3.0/4.5
3.0/4.5
3.0/4.5
3.0/4.5
3.0/4.5
• Boiler efficiency at nominal heat output
%
>93
>93
>93
>95
>95
>95
>95
• Flue gas mass flow at nominal output
Pellet moisture content 10 %
kg/h
20
32
38
57
63
77
90
• Flue gas mass flow rate at lowest nominal output
kg/h
6
9
11
16
19
22
26
•
Flow resistance wood pellet boiler
z-value
13
13
19
19
9
9
9
•
Hydraulic resistance at 10K
mbar
6
12
34
56
40
63
66
•
Hydraulic resistance at 20 K
mbar
2
4
10
15
11
17
18
• Water flow rate at 10 K
m³/h
0.69
1.12
1.29
1.97
2.15
2.66
3.09
• Water flow rate at 20 K
m³/h
0.34
0.56
0.65
0.99
1.08
1.33
1.55
•
Boiler water content
litres
40
40
52
52
78
78
78
•
Pellet hopper capacity
kg
90
90
90
90
90
90
90
•
Ash chamber content
litres
28
28
28
28
28
28
28
•
Thickness of thermal insulation on boiler body
mm
80
80
80
80
80
80
80
•
Boiler weight incl. casing
kg
360
360
390
390
440
440
440
Flue gas system
1
•
Minimum boiler draughting requirements
Pa
5 (1)
2
5 (1)
2
5 (1)
2
5 (1)
2
5 (1)
2
5 (1)
2
5 (1)
2
•
Electrical power consumption during operation
watts
50
70
90
110
140
150
160
•
Electrical power consumption during ignition
watts
300
300
300
300
300
300
300
•
Electrical power consumption during standby
watts
10
10
10
10
10
10
10
Fully automated pellet infeed (only in operation alternating with the wood pellet boiler)
•
Electrical power consumption during pellet infeed
watts
1900
1900
1900
1900
1900
1900
1900
•
Maximum current consumption
3
A
9
9
9
9
9
9
9
1
A draught limiter and explosion damper must be installed.
2
In borderline cases, a draughting requirement of 1 Pa at lowest output can be assumed for calculation purposes.
3
Fuse protection
minimum 16 a
because of operating current.
19
4 211 326 / 01
TEChnICAL InfORMATIOn