54
3.5 Spraying pump
The crop protection sprayer is equipped with a
centrifugal pump for the spraying system. The
pump is hydraulically driven via a proportional
valve and adjusts to the required quantities.
When the induction hopper or the internal clean-
ing is activated, the pump automatically runs with
its maximum capacity.
For pumps used require no pulsation dampen-
ing, because centrifugal pumps generate con-
tinuous flow and pressure.
The pump is almost completely maintenance
free and is equipped with a dry running protec-
tion. The pump must never be operated without
fluid, since this would damage the seals.
Fill the pump with fluid before initial
commissioning and after each drain-
ing before switching on.
All fluid residues must be drained off
in order to protect the pump against
frost damage.
Technical data
Type
Pumping
capacity
in l/min
at 0 bar
Pumping
capacity
in l/min
at 5 bar
max.
pressure
in bar
Hypro 9306 1000
500
10
ACE
FMC 750F-
HYD M22
1000
550
10.3
Pump ACE FMC 750F- HYD M22:
The pump has an oil filled cavity as dry running
protection and for cooling.
¾
Check the pressure gauge (4) every week
(2 bar).
¾
In case of a pressure drop check the oil level
and top up, if necessary (oil must be visible
in the inspection glass (3)).
¾
Change the oil if it is cloudy or discoloured.
Washing gun
The washing gun for cleaning the induction hop-
per after filling can be found inside the storage
door. Apart from this, deposited residues can be
flushed out of the canister.
20
Washing gun
¾
To control the handle actuation press the
button (20) during operation.
¾
Operate the handle to loosen.
¾
After switching off (19, previous page) relieve
the residual pressure.