INSTALLATION
3
27
RM640
www.honeywellprocess.com
34-VF-25-131 iss.1 GLO Feb 2019 US
3.5 Pressure and temperature ranges
Maximum process connection temperature and operating pressure
For more data on pressure ratings, refer to
Guidelines for maximum operating pressure
on page
139.
3.6 Recommended mounting position
We recommend that you prepare the installation when the tank is empty.
WARNING!
The process connection temperature range must agree with the temperature limits of the
gasket material. The operating pressure range is subject to the process connection used and the
flange temperature.
Figure 3-3: Pressure and temperature ranges
1
Temperature at the process connection
Non-Ex devices: The temperature range depends on the type of antenna, process connection and the seal material.
Refer to the table that follows.
Devices with Hazardous Location approvals: see supplementary instructions
2
Ambient temperature for operation of the display
-20...+70
°
C / -4...+158
°
F
If the ambient temperature is not between these limits, then it is possible that the display screen will not operate tem-
porarily. The device continues to measure level and send an output signal.
3
Ambient temperature
Non-Ex devices: -40...+80
°
C / -40...+176
°
F
Devices with Hazardous Location approvals: see supplementary instructions
4
Process pressure
Depends on the type of antenna and process connection. Refer to the table that follows.
Antenna type
Maximum process connection
temperature
Maximum operating pressure
[
°
C]
[
°
F]
[barg]
[psig]
PP Drop
+100
+212
16
232
PTFE Drop
+130
+266
16
232
Metallic Horn
+130
1
+266
1
16
232
1
The maximum process connection temperature must agree with the temperature limits of the gasket material
CAUTION!
Follow these recommendations to make sure that the device measures correctly. They have an
effect on the performance of the device.
Summary of Contents for RM640
Page 4: ...4 www honeywellprocess com 34 VF 25 131 iss 1 GLO Feb 2019 US ABOUT THIS DOCUMENT RM640 ...
Page 20: ...1 SAFETY INSTRUCTIONS 20 RM640 www honeywellprocess com 34 VF 25 131 iss 1 GLO Feb 2019 US ...
Page 56: ...4 ELECTRICAL CONNECTIONS 56 RM640 www honeywellprocess com 34 VF 25 131 iss 1 GLO Feb 2019 US ...
Page 120: ...6 OPERATION 120 RM640 www honeywellprocess com 34 VF 25 131 iss 1 GLO Feb 2019 US ...
Page 182: ...10 APPENDIX 182 RM640 www honeywellprocess com 34 VF 25 131 iss 1 GLO Feb 2019 US ...
Page 183: ...APPENDIX 10 183 RM640 www honeywellprocess com 34 VF 25 131 iss 1 GLO Feb 2019 US ...