C6.3
Contrast
The contrast control for the display screen.
You can select a shade of grey between light
grey (-10) and black (+10).
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting:
setting:
setting:
setting: User
min-max:
-10...+10
0
C6.4 1st Meas. Page
C6.4 1st Meas. Page
C6.4 1st Meas. Page
C6.4 1st Meas. Page
C6.4.1
Function
This menu item changes the configuration
of data shown on the display screen in
Normal mode. There are two measurement
pages available to show readings in Normal
mode. This setting is for the first page.
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting:
setting:
setting:
setting: User
One Value, One Value &
Bar, Two Values, Two
Values & Bar, Three
Values
One Value &
Bar
C6.4.2
1st Value
Variable
This changes the measurement type of the
first value on the measurement page.
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting:
setting:
setting:
setting: User
Level, Distance, Sensor
Value, Reflection
2
Distance
C6.4.3
0% Range
This is the 0% value given to the bar graph
indicator in Normal mode. The range is
related to the measurement type set in
C6.4.2 1st Value Variable. This menu item is
only available if you set C6.4.1 Function to
"One Value & Bar" or "Two Values & Bar".
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting:
setting:
setting:
setting: User
Refer to "Function
description".
Refer to
"Function
description".
C6.4.4
100% Range
This is the 100% value given to the bar graph
indicator in Normal mode. The range is
related to the measurement type set in
C6.4.2 1st Value Variable. This menu item is
only available if you set C6.4.1 Function to
"One Value & Bar" or "Two Values & Bar".
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting:
setting:
setting:
setting: User
Refer to "Function
description".
Refer to
"Function
description".
C6.4.5
Format 1st
Value
You can change the number of decimal
places that are shown for the first value on
the measurement page in Normal mode.
For example, if you set this menu item to
"X.XX", the value shown will be corrected to
2 decimal places. If you set this menu item
to "Automatic", the device will adjust the
number of decimal places automatically.
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting:
setting:
setting:
setting: User
X, X.X, X.XX, X.XXX,
X.XXXX, X.XXXXX,
X.XXXXXXX, Automatic
X.XXX
C6.4.6
2nd Value
Variable
This changes the measurement type of the
second value on the measurement page.
This menu item is only available if you set
C6.4.1 Function to "Two Values", "Two
Values & Bar" or "Three Values".
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting:
setting:
setting:
setting: User
Level, Distance, Sensor
Value, Reflection
2
Level
Menu No. Function
Function description
Selection list
Default
Summary of Contents for RM640
Page 4: ...4 www honeywellprocess com 34 VF 25 131 iss 1 GLO Feb 2019 US ABOUT THIS DOCUMENT RM640 ...
Page 20: ...1 SAFETY INSTRUCTIONS 20 RM640 www honeywellprocess com 34 VF 25 131 iss 1 GLO Feb 2019 US ...
Page 56: ...4 ELECTRICAL CONNECTIONS 56 RM640 www honeywellprocess com 34 VF 25 131 iss 1 GLO Feb 2019 US ...
Page 120: ...6 OPERATION 120 RM640 www honeywellprocess com 34 VF 25 131 iss 1 GLO Feb 2019 US ...
Page 182: ...10 APPENDIX 182 RM640 www honeywellprocess com 34 VF 25 131 iss 1 GLO Feb 2019 US ...
Page 183: ...APPENDIX 10 183 RM640 www honeywellprocess com 34 VF 25 131 iss 1 GLO Feb 2019 US ...