Section 7 - System Programming
7–25
RF zone numbers must begin after assigned hardwired zone numbers. For example, if zones 1
through 4 were hardwired, the first RF zone number assigned is 5.
UL
RF has not been evaluated by UL and must not be used for UL installations.
Any zone using an RF point must be enabled in this question so that the system knows where to look
for zone data.
To disable a RF point that has been previously programmed:
1. Remove the RF enable for the appropriate zone in Question 26; and
2. Make the first 2 digits in the RF programming for that zone “00.”
Question 26, L3 - Disable Account
Default = A
This option is enabled when L3 is set to D. All other entries for L3 will not enable this option. While
this option is enabled, the system does not arm; and the Reporting code is transmitted, with user
number trying to arm (if the dialer format requires it), to the CS. If the format is CID, the code for this
event is 551 (Dialer Disabled Event code).
Question 26, L4 - Pager Options/Exit Bypass
Default = 0
For additional pager options, refer to Question 10, Location 4.
UL
The Pager has not been evaluated by UL and must not be used for UL installations.
Refer to the chart below to select the following options.
Digit ENABLE
#58
PAGER OPEN/CLOSE
USER SELECT
PAGER 2
ATTEMPTS EXIT
BYPASS
0 None
1
9
2
9
3
9
9
4
9
5
9
9
6
9
9
7
9
9
9
8
9
9
9
9
A
9
9
B
9
9
9
C
9
9
D
9
9
9
E
9
9
9
F
9
9
9
9
Summary of Contents for OMNI 408
Page 6: ...vi ...
Page 28: ...OMNI 408 OMNI 408EU Installation and Setup Guide 5 4 ...
Page 72: ...OMNI 408 OMNI 408EU Installation and Setup Guide 8 4 ...
Page 98: ...OMNI 408 OMNI 408EU Installation and Setup Guide D 4 ...
Page 100: ...OMNI 408 OMNI 408EU Installation and Setup Guide E 2 ...
Page 103: ......