OMNI-408/OMNI-408EU Installation and Setup Guide
7–22
QUESTION 19
CS CODES for AMBUSH and AC LOSS
DEFAULT = AAAA
There are 4 locations (L1-L4) in this question as follows:
Question 19, L1 & L2 - Ambush Code
Default = AA
If an Ambush code is defined, User no. 6 is the Ambush code. The same rules apply here regarding
dialer format. If transmission is not desired, program AA in locations L1 and L2.
NOTE:
Ambush transmissions are immediate and cannot be aborted.
Question 19, L3 & L4 - AC Loss Code
Default = AA
The same rules apply here regarding dialer format. If transmission is not desired, program AA in
locations L3 and L4.
NOTE:
AC loss is reported 15 minutes after detection.
QUESTION 20
CS CODES for PANIC and LOW BATTERY
DEFAULT = 22AA
There are 4 locations (L1-L4) in this question:
Question 20, L1 & L2 - Panic Code
Default = 22
The same rules for programming regarding dialer format apply here. If transmissions are not desired,
program AA in locations L1 and L2.
NOTE:
Panic transmissions are immediate and cannot be aborted.
Question 20, L3 & L4 - Low Battery Code
Default = AA
The same rules for programming regarding dialer format apply here. If transmissions are not desired,
program AA in locations L3 and L4. Low-battery transmissions are reported 4 minutes after detection.
Low-Battery Restore Code is reported within 4 minutes after detection of good battery condition.
QUESTION 21
CS CODES for OPEN/CLOSE and CS TEST
DEFAULT = AAAA
There are 4 locations (L1-L4) in this question:
Question 21, L1 - Opening Code
Default = A
Question 21, L2 - Closing Code
Default = A
L1 is the single-digit Opening code. L2 is the single-digit Closing code. Entry of AA into these two
locations means that openings and closings are not desired. If a dialer format other than standard is
programmed, the second digit transmitted is the user number.
Question 21, L3 & L4 - CS Test Code
Default = AA
L3 - L4 is the CS Test code. The CS Test code is transmitted at the interval selected in Question 09,
Location 3.
NOTE:
Any digit entered is transmitted unless CS Test is disabled; to disable CS Test, see Question 09,
Location 3.
Summary of Contents for OMNI 408
Page 6: ...vi ...
Page 28: ...OMNI 408 OMNI 408EU Installation and Setup Guide 5 4 ...
Page 72: ...OMNI 408 OMNI 408EU Installation and Setup Guide 8 4 ...
Page 98: ...OMNI 408 OMNI 408EU Installation and Setup Guide D 4 ...
Page 100: ...OMNI 408 OMNI 408EU Installation and Setup Guide E 2 ...
Page 103: ......