Section 7 - System Programming
7–5
Question 06, L4
K.P. Panic, Swinger Shutdown, Zone Restore, & System Bell Test
Default = 1
Enter the digit for the desired system options from the table below in Location L4.
NOTE:
The checkmarks highlight which options are selected.
KEYPAD PANIC
SYSTEM DIAL DELAY
Digit
AUDIBLE SILENT
SWINGER
SHUTDOWN
TRANSMIT
ZONE RESTORE
15 SEC
30 SEC
0
9
9
1
9
9
2
9
9
9
3
9
9
9
4
9
9
9
5
9
9
9
6
9
9
9
9
7
9
9
9
9
8
9
9
9
9
9
A
9
9
9
B
9
9
9
C
9
9
9
D
9
9
9
E
9
9
9
9
F
9
9
9
9
KEYPAD SILENT/AUDIBLE PANIC
- Determines whether the keypad panic condition [*] [#]
(entered on the keypad) activates the bell and the keypad buzzer. In either case, a signal is transmitted
to the central station if a Panic code has been programmed.
NOTE:
The keypad panic condition can be enabled through Question 07, Location 1.
SWINGER SHUTDOWN
- If selected, activation of the same zone 3 times within the same arming
interval does not activate the bell or the dialer. Swinger shutdown is not meant for any 24-hour type
zones; choosing this feature for the wrong zone type could cause problems in zone operation.
UL
For UL installations, Swinger Shutdown must not be selected.
TRANSMIT ZONE RESTORE -
If enabled, this option enables the transmission of zone restores
along with the system restores (AC loss, low battery, etc.). If not enabled, the ONLY restores
transmitted are the system restores (see Question 19, Location 2).
SYSTEM DIAL DELAY
- If this option is selected, all zones have capability of a 15- or 30-second dial
delay before reporting to the CS. Each individual zone must be enabled in Questions 11-18, Location 4.
Summary of Contents for OMNI 408
Page 6: ...vi ...
Page 28: ...OMNI 408 OMNI 408EU Installation and Setup Guide 5 4 ...
Page 72: ...OMNI 408 OMNI 408EU Installation and Setup Guide 8 4 ...
Page 98: ...OMNI 408 OMNI 408EU Installation and Setup Guide D 4 ...
Page 100: ...OMNI 408 OMNI 408EU Installation and Setup Guide E 2 ...
Page 103: ......