OMNI-408/OMNI-408EU Installation and Setup Guide
7–10
Digit
EXIT TIMEOUTS
Digit
EXIT TIMEOUTS
0
1 second
8
1 minute 20 seconds
1
10 seconds
9
1 minute 30 seconds
2
20 seconds
A
1 minute 40 seconds
3
30 seconds
B
1 minute 50 seconds
4
40 seconds
C
2 minutes
5
50 seconds
D
2 minutes 10 seconds
6
1 minute
E
2 minutes 20 seconds
7
1 minute 10 seconds
F
3 minutes
Question 08 L3
Burglary Bell Cutoff
Default = 5
Enter the desired bell cutoff time on alarm conditions for burglary and panic in 3-minute intervals (for
example, 3 = 9 minutes). The valid range of input is 1 - F, with F indicating an infinite burglary bell
cutoff time.
Digit
BURGLARY & FIRE
BELL TIMEOUTS
Digit
BURGLARY & FIRE
BELL TIMEOUTS
1 3
minutes
9 27
minutes
2
6 minutes
A
30 minutes
3
9 minutes
B
33 minutes
4
12 minutes
C
36 minutes
5
15 minutes
D
39 minutes
6
18 minutes
E
42 minutes
7 21
minutes
F Infinite
8 24
minutes
UL
Must be programmed as “2” for UL installations.
Question 08, L4
Fire Bell Cutoff
Default = F
Using the table in Question 08, Location 3 to determine valid choices, enter the desired bell cutoff time
for fire conditions in 3-minute intervals (for example, 3 = 9 minutes). The valid range of input is 1 - F,
with F indicating an infinite fire bell cutoff time.
UL
Must be programmed as “2” for UL installations.
Summary of Contents for OMNI 408
Page 6: ...vi ...
Page 28: ...OMNI 408 OMNI 408EU Installation and Setup Guide 5 4 ...
Page 72: ...OMNI 408 OMNI 408EU Installation and Setup Guide 8 4 ...
Page 98: ...OMNI 408 OMNI 408EU Installation and Setup Guide D 4 ...
Page 100: ...OMNI 408 OMNI 408EU Installation and Setup Guide E 2 ...
Page 103: ......