OMNI-408/OMNI-408EU Installation and Setup Guide
7–14
DISARM BELL TEST
- Choosing this option causes a 1-second bell output when system disarms (or a
single chirp if the Bell Test Chirp option is selected).
BELL TEST CHIRP
- This option is for use with sirens that respond quickly to an output. If selected,
this option shortens both the Arming Bell Test (double chirp) and Disarm Bell Test (single chirp) from a
1-second to a 100-mS output.
Question 10, L2
Instant Led Pulse, Open/Close Users 4/12, Temporal Bell
Default = 0
Digit
INSTANT LED
PULSE
O/C USERS
4/12
TEMPORAL
BELL
0 None
1
9
2
9
3
9
9
8
9
9
9
9
A
9
9
B
9
9
9
INSTANT LED PULSE
- Choosing this option causes the Instant LED to reflect the CS monitoring
status. When selected, by either the installer or a download, a pulsing Instant LED indicates to the
user that the CS is not monitoring their account.
All dialer functions are maintained, regardless of whether the Instant LED Pulse option is
selected or not.
O/C USERS 4/12
- If this option is selected (along with other open and close codes programmed), only
keypad User Code 4 and keyfob User Code 12 can report open and close signals. No other user codes
will report to the CS.
TEMPORAL BELL
- If this option is selected, the fire bell becomes temporal: 500mS on/500mS
off/500mS on/500mS off/1 second off. The temporal output option is available for fire conditions. If not
selected, the fire bell output will be pulse.
UL
Temporal Bell must be enabled for UL installations.
Summary of Contents for OMNI 408
Page 6: ...vi ...
Page 28: ...OMNI 408 OMNI 408EU Installation and Setup Guide 5 4 ...
Page 72: ...OMNI 408 OMNI 408EU Installation and Setup Guide 8 4 ...
Page 98: ...OMNI 408 OMNI 408EU Installation and Setup Guide D 4 ...
Page 100: ...OMNI 408 OMNI 408EU Installation and Setup Guide E 2 ...
Page 103: ......