40X ZOOM IR PTZ DOME CAMERA USER GUIDE
77
4.
To start recording video when the event is detected, select the
Record
check box.
5.
In the
Record Delay
field, enter the number of seconds that the system will
continue to record video after the event has ended. Enter a value between
10
and
300
.
6.
To generate an alarm output when the event is detected, select the
Alarm Output
check box and select the alarm output(s) to be activated.
7.
In the
Alarm Delay
field, enter the number of seconds that the system will
continue to generate an alarm output after the event has ended. Enter a
value between
10
and
300
.
8.
Click
Save
to apply the settings.
Configuring Illegal Access
An illegal access event occurs when a specified number of unsuccessful login
attempts is exceeded.
To enable illegal access detection:
1.
On the
Illegal Access
tab, select the
Enable
check box.
2.
In the
Failed Login Attempts
field, enter the number of unsuccessful login
attempts the system will allow before an illegal access event is detected.
Enter a value between
3
and
10
.
3.
To generate an alarm output when the event is detected, select the
Alarm Output
check box and select the alarm output(s) to be activated.
4.
In the
Alarm Delay
field, enter the number of seconds that the system will
continue to generate an alarm output after the event has ended. Enter a
value between 10 and 300.
5.
To send an email notification when an illegal access event is detected,
select the Send Email check box. Email settings must be configured in
Setting
Network
SMTP (Email)
.