40X ZOOM IR PTZ DOME CAMERA USER GUIDE
65
Action
Configure intrusion action, and you can select
Appear
or
Cross
.
Direction
Select the crossing direction from
Enters
,
Exits
, and
Enter & Exit
.
4.
Click
Save
.
Abandoned Object
An alarm will be triggered when the selected target in the monitoring scene stays in the
screen for more than the set time.
Pedestrians or vehicles that stay for too long would be regarded as abandoned objects.
To filter out such alarms, you can use
Target filter
. In addition, the duration can be
properly extended to avoid false alarm due to a short stay of people.
Applicable scenes: Scenes with sparse targets, no obvious and frequent light changes.
For scenes with intensive targets or too many obstacles, missed alarms would increase;
for scenes in which too many people stay, false alarms would increase. Select
detection areas with simple texture, because this function is not applicable to scenes
with complex texture.
1.
Select
Abandoned Object
from the
Rule Type
list. The configuration interface is
displayed.
2.
Click
Draw Rule
, and you can draw rules on the monitoring screen. For parameter
description.
3.
Click
Clear
to the right of
Draw Rule
, and you can clear all drawn rules.
4.
Configure parameters as needed. For the parameter description.
Table 9 Abandoned Object Parameter
Parameter
Description
Duration
For abandoned object, the duration is the shortest time to trigger an alarm
after an object is abandoned.
5.
Click
Save
.