5.3
CONTROL OPTIONS, CONTINUED
5.3.5 Default
Function
Select
5
to set the default function. The Default Function can be enabled or disabled.
To set the Default Function, enter values and select
Enter
(F5 on the HJZTP controller)
when done.
Rev. 1.02
35
900.0679
22-June-2006
If:
Then:
Default Function is disabled Scan remains at its present position until the scan
receives a control command.
Default Function is enabled,
and the scan is idle for the
programmed Delay setting
The scan performs the function (PreShot, VectorScan,
or Tour) programmed in the default function setup
menu after the programmed delay with no activity.
Alarms are present and the
scan reaches the delay
setting
The scan automatically acknowledges the current
alarm, resets its delay timer, and then processes the
next alarm in numerical order. The scan processes all
alarms in this manner before performing the default
function.
Field
Usage
FUN (function)
Enter the function to perform after being idle for the specified delay
time. P = PreShot; V = VectorScan, T = Tour. See instructions
below for entering these functions in the FUN field.
NUM
(number)
Enter the PreShot number (0-99), VectorScan number (0-9), or
Tour number (1-3). Depending on the control system being used,
specific PreShots may be used for special setup and control
functions and are not available for the default function. Refer to
Table
4
and
Table 5
for reserved PreShot numbers.
DLY (delay
Enter the amount of time (minutes: seconds) the scan should be idle
before performing the default function. Maximum delay is 99 minutes
and 59 seconds.
ENA (enable)
Enter Y to enable or N to disable the default function.
DEFAULT FUNCTION SETUP
FUN
NUM
DLY
ENA
P
_1
_ _ : _ _
Y
PVT
MIN:SEC
Select ‘Enter” when done.
CONTROL OPTIONS
1 PASS................................................ON
2 Auto-Pivot ........................................ON
3 Program Alarms
4 Set Pan and Tilt Options
5 Set Default Function
6 Auto Focus ......................................... Z
7 VectorScan Auto Focus ................ OFF
8 Pan Offset
ESC to Exit
Summary of Contents for HD6 Series
Page 1: ...HD6 Series PTZ Camera in a Dome User Manual 900 0679 June 2006 Rev 1 02 ...
Page 4: ...Rev 1 02 iv 900 0679 22 June 2006 ...
Page 18: ...Rev 1 02 4 900 0679 22 June 2006 Notes ...
Page 32: ...Rev 1 02 18 900 0679 22 June 2006 Notes ...
Page 38: ...Rev 1 02 24 900 0679 22 June 2006 Notes ...
Page 96: ...Rev 1 02 82 900 0679 22 June 2006 Notes ...
Page 122: ...Rev 1 02 108 900 0679 22 June 2006 Notes ...
Page 130: ...Rev 1 02 116 900 0679 22 June 2006 Notes ...
Page 134: ...Rev 1 02 120 900 0679 22 June 2006 Notes ...
Page 143: ...14 9 HD6 SCAN CONTINUED Rev 1 02 129 900 0679 22 June 2006 ...
Page 148: ...Rev 1 02 134 900 0679 22 June 2006 Notes ...
Page 149: ...Rev 1 02 135 900 0679 22 June 2006 Notes ...
Page 150: ...Rev 1 02 136 900 0679 22 June 2006 Notes ...